Reelcraft Static Discharge Reels GA3100 User Manual

Operating instructions, Static discharge reel, Warning

Advertising
background image

Operating Instructions

Reelcraft Industries, Inc. • 2842 E Business Hwy 30, Columbia City, IN 46725

Ph: 800-444-3134 / 260-248-8188 • Fax: 800-444-4587 / 260-248-2605

Customer Service: 855-634-9109 • [email protected] • www.reelcraft.com

Rev: 5/2012

Dimensions

GA3100 N

Static Discharge Reel

Model Number:

A

9.25”

B

4.31”

C

9.75”

A

B

C

Grounding plugs / clamps shall not be allowed to drag across ramp.

Clamps / plugs shall be carried to reels on equipment.

Replace cable with 100’ maximum 3/32” x 5/32” grounding cable, with maximum coating OD of 1/8”.
Pre-wind the reel 54 to 55 full turns clockwise. Attach cable and allow it to slowly retract into the
reel.

Do not operate this product without the appropriate pre-wind on the reel. Over pre-winding or under
pre-winding of the reel may damage the power spring.

Failure to follow the above warnings may cause personal injury and damage to the reel.