Ross Controls SHUTTLE VALVES SERIES 19 User Manual

Series 18 &19 quick exhaust and shuttle valves, Shuttle valves, Quick exhaust valves

Advertising
background image

6

© 2012,

ROSS CONTROLS

®

.

All Rights Reserved.


Valve Port Valve Model

Avg.

Dimensions inches (mm)

Weight

Type Size

Number

C

V

A

B

C

lb (kg)

Y

1/8

1968E1006

0.8

1.98 (50)

1.25 (32)

0.75 (19)

0.15 (0.07)

1/4

1968E2006

0.8

1.98 (50)

1.25 (32)

0.75 (19)

0.15 (0.07)

Z

1/4

1968D2003

2.0

2.64 (67)

2.13 (54)

1.25 (32)

0.8 (0.4)

3/8

1968D3003

3.0

2.64 (67)

2.13 (54)

1.25 (32)

0.8 (0.4)

Shuttle Valves

Z

Y

Quick Exhaust Valves

Port Size

Valve Model

Avg. C

V

Dimensions inches (mm)

Weight

In-Out Exh.

Number

In-Out Out-Exh.

A

B

C

lb (kg)

3/8

1/2

1868A3005

2.9

3.4

3.2 (81)

4.7 (119) 2.0 (51) 1.0 (0.5)

1/2

1/2

1868A4005

2.9

3.4

3.2 (81)

4.7 (119) 2.0 (51) 1.0 (0.5)

3/4

1

1868A5005

7.2

10

4.3 (110)

6.5 (165) 2.6 (65) 2.5 (1.1)

1

1

1868A6005

7.2

10

4.3 (110)

6.5 (165) 2.6 (65) 2.5 (1.1)

STANDARD SPECIFICATIONS: For valves on this page.
Ambient/Media Temperature: 40° to 175°F (4° to 80°C).
Flow Media: Filtered air; 5 micron recommended.
Inlet Pressure: 5 to 150 psig (0.3 to 10 bar).

Signal Pressure: Must be equal to or greater than inlet.
Port Threads: NPT standard, BSPP. For BSPP threads add a “D”
prefix to the model number, e.g. D1868A3005.

Quick cylinder reversal can be a problem if the control valve is at a distance from the

cylinder or otherwise restricts the exhaust flow. A ROSS quick exhaust valve near the
cylinder opens as soon as the controls valve begins exhausting, and thus allows quick
reversal of the cylinder.

ROSS shuttle valves have two inlets and one outlet. The first inlet to be pressurized
is connected to the outlet, and the second inlet is then closed. Thus, a pneumatic
device connected to the shuttle outlet can be operated by either of two control valves
connected to the shuttle inlets.

Automatically blocks one inlet passage when
pressure is applied to the secont inlet. Pressure
to either inlet is channelled to one outlet port.

Series 18 &19 Quick Exhaust and Shuttle Valves

Type Z

IMPORTANT NOTE: Please read carefully and thoroughly all of the CAUTIONS on the inside back cover.

Advertising
This manual is related to the following products: