Series SV27 Sensing Valves

Pilot Operated Check

Solenoid Pilot Controlled and

Pressure Controlled

Category 2 & 3 Safety Applications

Load Holding

ROSS’ new Series SV27 Sensing Valves Pilot Operated

Check, based upon the proven Series 27 valve family, combine
the tough, dirt tolerant characteristics of poppet technology with
sensing for actual internal position and state. Electrical feedback
is provided via a positively-driven, safety-rated DPST (Double-
Pole Single-Throw) switch with both normally open (NO) and
normally closed (NC) contacts. The DPST switch is actuated
whenever the valve is not in the normal home position.

An optional visual pressure indicator (988A30) or pressure

switch kit (608A86) can be installed into the 1/8 NPT pressure
verifi cation port (PV) for verifi cation of pressure release.

www.rosscontrols.com

New Product

Information

• Pressure controlled and solenoid pilot controlled versions.
• Poppet construction for near zero leakage & high dirt tolerance.
• Directly operated safety-rated force-guided positive-break
status switch (DPST).
• Holds a vertical load in the event of loss of air pressure
(and electrical power with solenoid pilot operated models).

FEATURES:

EN 954-1, ISO 13849-1,

& AS4024-1

(3/4 bodies only,

other sizes approval pending)

1/4” Signal port

1/8” PV

C

V

V

C

1/8” EPS

1/8” PV

Sensing Valves PO Check

Pressure Controlled

Sensing Valves Redundant PO Check

V

1/4” Signal port

1/8” PV

C

1/4” Signal port

1/8” PV

C

V

1/8” PV

1/8” EPS

1/8” PV

1/8” EPS

Pressure Controlled

Sensing Valve PO Check

Pressure Controlled

Sensing Valve Redundant PO Check

Pressure Controlled

GENERAL:

STANDARD SPECIFICATIONS:

Solenoid:

AC or DC power. Rated for continuous duty.

Standard Voltages:

110 volts AC, 50/60 Hz; 24 volts DC.

Other voltages available.
Power Consumption:

CNOMO Style:

11 VA inrush, 8.5 VA holding on 50 or 60 Hz;

6 watts on DC.
Pacer Style:

87 VA inrush, 30 VA holding on 50 or 60 Hz;

14 watts on DC.
Ambient Temperature:

40° to 120°F (4° to 50°C).

Media Temperature:

40° to 175°F (4° to 80°C).

Flow Media:

Filtered air 5 micron recomended.

Inlet Pressure:

40 to 150 psig (2.8 to 10 bar).

Pilot Pressure:

Equal to or greater than inlet pressure.

Switch Current/Voltage Max.:

2.5 A/120 volts AC.

Switch Current/Voltage Min.:

50 mA/24 volts DC.

NOTE: Electrical life of switch varies with conditions and
voltage; rated in excess of 15 million cycles.