Atwood Mobile Products HYDRO FLAME 2H2C User Manual

Hydro flame, Model 2h2c two stage furnace digital thermostat, Furnace operation

Advertising
background image

ENGLISH, FRANCAIS

(et Canada)

•Installation •Operation

Effective 1/08

LITERATURE NUMBER

MPD 31493

hydro flame

TM

Model 2H2C

Two Stage Furnace

Digital Thermostat

FOR TWO STAGE FURNACE

9

1

12VDC

Ground

3

+12VDC

2

NOT

USED

Screw Mounting Holes

4

RELAY

COM

*

5

A/C

COM-

PRESSOR

6

A/C

HI

FAN

7

A/C

LOW

FAN

8

TH FROM
FURNACE

(CLIM) COOL

FAN (VENTIL.)

(OFF) OFF

HEAT (CHAUFFAGE)

M

Display

System Switch

Temperature
Set

Mode
Set

Specifications

Operating Voltage

......................

9VDC to 18VDC

Power Consumption

................................

100mA

Operating Temperature

..................

-40F to +185F

Room Temperature Range

..............

+55F to +90F

Room Temperature Display Range

..

+35F to +99F

Thermostat Accuracy

................................

+/- 1F

System Slide Switch

SCROLL ORDER OF

LEFT

RIGHT

DISPLAYED MODES

OPERATION

COOL

OFF

HEAT

FAN

Scroll Order of Displayed Modes

Furnace Operation

AU

Furnace automatically switches between high and low BTU valve and high
and low speed fan when cycling to satisfy set point.

HI

Furnace high BTU valve and high speed furnace fan cycle to satisfy set point.

LO

Furnace low BTU valve and low speed furnace fan cycle to satisfy set point.

HF

Furnace fan runs at high speed to circulate air. Air conditioner fan does not run.

LF

Furnace fan runs at low speed to circulate air. Air conditioner fan does not run.

COOL

OFF

HEAT

FAN

Scroll Order of Displayed Modes

Air Conditioner Operation

AU

Air conditioner automatically switches compressor and high and low speed fan when
cycling to satisfy set point.

HI

Air conditioner compressor and high speed fan operate to satisfy set point.

LO

Air conditioner compressor and low speed fan operate to satisfy set point.

HF

Air conditioner fan runs at high speed to circulate air. Furnace fan does not run.

LF

Air conditioner fan runs at low speed to circulate air. Furnace fan does not run.

COOL

OFF

HEAT

FAN

Scroll Order of Displayed Modes

Fan Operation

HI

Air conditioner fan and furnace fan run at high speed to circulate air.

LO

Air conditioner fan and furnace fan run at low speed to circulate air.

COOL

OFF

HEAT

FAN

Scroll Order of Displayed Modes

Off

OF

No operation occurs.

THERMOSTAT INSTALLATION

Thermostat is very sensitive.

HANDLE WITH CARE AT ALL TIMES

.

Locate thermostat 48˝ to 54˝ above floor on an

INTERIOR

wall.

Pick a dry area where air circulation is good.

EXTERIOR

wall

location must have a 3/4˝ spacer between thermostat and
exterior wall.

1. Be sure all electrical power has been disconnected from

the air conditioner, furnace and the power supply.

2. Do not install the thermostat where there are unusual

heating conditions: such as direct sunlight, heat produc-
ing appliances (television, radio, wall lamp, etc.)
or a furnace or air conditioner supply register.

3.

ATTACHING THE WALL THERMOSTAT

. Separate the thermostat

body from the sub-base by gently squeezing the top and
bottom. Pull wires through access hole in base plate.
Attach thermostat sub-base to the wall at the desired
mounting location. Mount the sub-base to the wall before
connecting the wires.

THIS THERMOSTAT HAS BEEN DESIGNED TO OPERATE STANDARD AIR CONDITIONING UNITS IN CONJUNCTION WITH AN EXCALIBUR

2

-

STAGE FURNACE

.

*Note: Move jumper to

positions 3 and 4 for RVP
Unit. Discard jumper for
Dometic

®

.