MAHLE RTI NTF-15H User Manual

Auto tire fill system, Operation instructions, Over pressure setting (ops)

Advertising
background image

OPS
N2P

OPS
N2P

RTI Technologies, Inc.
10 Innovation Drive
York, Pennsylvania 17402 USA
Phone: 717-840-0678
Website: www.rtitech.com
E-mail: [email protected]

Auto Tire Fill System

Operation Instructions

1. Verify “Red” slider valve is in down position
2. Attach air supply (150 PSI max) to NTF unit
3. Plug in the Auto Tire Fill System
4. Turn both valves on NTF unit to “FILL TIRE”
5. Connect hoses to tires
6. Set the final target pressure by pressing + or - buttons
7. To change Over Pressure and Nitrogen Purge Cycles

Settings, see sections below

8. Move “Red” slider valve to up position
9. Press N2 button once for Standard Inflation,
or

hold

N2 button to invoke Nitrogen Purge Cycle

- Standard Inflation will inflate or deflate to the

target pressure

- One complete Nitrogen Purge Cycle is the
process in which the Auto Tire Fill System will
deflate to 3 PSI, Inflate to target pressure, deflate
to 50% of target pressure, then inflate to final target
pressure (If 2 or more Nitrogen Purge Cycles are
programmed, the above process will be repeated)

10. When unit beeps 5 consecutive times, slide “Red”

valve to down position

11. Wait 10 seconds before disconnecting hoses

Over Pressure Setting (OPS)

1. Plug in the Auto Tire Fill System
2. Press

button ONCE

3. Press + or - buttons to change the Over Pressure

Setting

4. Press N2 button to save the Over Pressure Setting

Nitrogen Purge Cycle Setting (N2P)

1. Plug in the Auto Tire Fill System
2. Press

button TWICE

3. Press + or - buttons to change the number of Purge

Cycles

4. Press N2 button to save the number of Purge Cycles

Buzzer Volume Setting

1. Make sure the Auto Tire Fill System is unplugged
2. Press and hold N2 button and - button simultaneously
3. While holding N2 button and - button, plug in the

Automatic Inflation Unit

4. When “Vol” appears on the screen, release the N2

button and - button

5. Adjust the volume using the + and - buttons
6. Press the N2 button to save the volume setting

Inlet Port

Red Slider Valve

Silencer Plug

Error Messages

Error

Possible Cause

Solution

ER1

Unstable pressure

Verify that air chuck is pressed
all the way onto the tire

ER2

Unstable pressure,
incorrect supply pressure,
or Inflate/deflate valve
connections are reversed

Verify that air chuck is pressed
all the way onto the tire. Check
valve connections on PCB.

ER3

Low or no supply pressure

Verify that air chuck is pressed
all the way onto the tire

ER4

Initial or final pressure is
too high, exceeds
maximum pressure by
more than 20 psi, 140
kPa, or 1.4 bar

Turn bottom valve on NTF unit
to vacuum tire. Turn off power
for a minimum of 5 seconds. If
error reappears, call RTI

ER5

Low supply voltage

Check power supply, message
will clear when correct voltage
is restored

ER6

Program or PCB error

Turn off power for a minimum of
5 seconds. If error reappears,
call RTI

ER8

Calibration error

Calibration required, call RTI

ER9

Calibration error

Turn off power for a minimum of
5 seconds. If error reappears,
call RTI

Troubleshooting

Problem

Possible Cause

Solution

No Display

No power supply to
Auto Inflation Unit

Check power
supply

The display will not
move or is stuck on a
particular value

Switch is damaged

Call RTI

The unit deflates very
slowly

The silencer plug on
the valve is blocked

Remove and clean
silencer plug

The Auto Inflation
Unit no longer beeps

The beeper is
damaged

Call RTI

The inflation process
commences but does
not complete

Low supply pressure

Verify that air chuck
is pressed all the
way onto the tire