Model with exhaust gas return valve – HATZ Diesel 4M42 User Manual

Page 46

Advertising
background image

Step

Activity

4

As soon as the engine is running, release the starting key.
▪ The starting key springs back to position "I" and remains in

this position during operation.

▪ The charge control (2) and oil pressure display (3) go out.
▪ The operating display (1) lights up.

NOTICE

i

▪ In case of irregularities, switch off the engine immediately.
▪ Identify the fault and eliminate it.
▪ For details of troubleshooting, see the chapter 9 Faults,

page 93.

Model with exhaust gas return valve

The engines 4L42C and 4M42 are equipped with an exhaust gas return
valve (EGR). The indicators change as follows:

Pos.

Designation

5

Indicator EGR

Blink codes

The indicator (5) only flashes during operation if a problem arises in connec-
tion with the exhaust gas return system. This includes a dirty air filter. This
can be identified by the following flash code of the indicator (5):
▪ 7 times short flash (approx. 0.5 seconds) and 1 long flash (approx. 1.5

seconds).

▪ The flash code indicates that the air filter must be cleaned or changed

(see the chapter 8.2.11 Checking and cleaning the air filter cartridge,
page 76
).

▪ If a different flash code appears, please contact the nearest Hatz service.

Operation and use

2-4L41C, 2-4M41, 2-4M41Z, 4L42C, 4M42

46

Operator's Manual

HATZ

Advertising
This manual is related to the following products: