BELT TENSIONER

48" Mega Flow Fan

Warning!

Disconnect All Electrical Power To Fan Before Installing Belt Tensioner

Always Double Check Power Sources.

KIT INCLUDES:

1011-5001 Belt Tensioner

1004-1402 Screw 1/4-20 (4)

1001-1446 Lock Nut 1/4-20 (4)

1022-3000 Belt AP-44

Tools Required:

Cordless drill

17/64 in. (0.67 cm) drill bit

3/8 in. (9.5 mm) Drive ratchet

6" (15.2 cm) Extension for ratchet

7/16 in. (11 mm) Socket

7/16 in. (11 mm) Wrench

Installation

1. Disconnect electrical power to fan.

2. Remove fan belt from motor & pulley.

3. Position belt tensioner 1.75" (4.44 cm) from

chamfered edge of bottom of flange as shown
in diagram below.

4. Mark the four holes of belt tensioner.

5. Drill four 17/64" holes in support brace.

6. Fasten belt tensioner to support brace with

screws (1004-1402) & lock nuts (1001-1446)
provided.

7. Use straight edge. Align prop pulley with

pulley on belt tensioner.

8. Use straight edge. Align motor pulley with

pulley on belt tensioner.

9. Make sure set screws on pulleys are tight.

Recommended torque settings: Prop pulley
110 In. Lb. Max.; Motor pulley 110 In. Lb. Min.

10. Roll fan belt onto pulleys.

11. Installation complete.