Hired-Hand Funnel Flow Fans: 6 FF Face Mount Adapter Plate User Manual

36" ff face mount adapter plate, Removal of wire guard, shutter, and power cord, Removal of prop and existing motor

Advertising
background image

HIRED-HAND, INC. 1733 Co Rd Bremen, AL 35033 Phone 256-287-1000 Fax 256-287-2000

Manual Part No. 4801-0167

Removal Of Wire Guard, Shutter,
And Power Cord

1. If the fan has a funnel flow cone, remove the wire

guard from the cone. If the fan does not have a
cone, remove the wire guard from the fan
housing.

2. Remove the shutter from the back of the fan.
3. CAUTION: Make sure that the power cord is

unplugged from the outlet. Remove the power
cord from the existing motor. Retain the power
cord for use with the replacement motor.

Removal Of Prop And Existing Motor

1. Loosen the set screw on the prop and remove

prop.
Note: Retain the metal key for reinstallation of the
prop.

2. Remove the four 5/16” carriage bolts holding the

existing motor and remove motor from mount
bracket. Note: Retain the carriage bolts and nuts
for attachment of the Face Mount Adapter Plate.

Installation Of Face Mount Adapter Plate

1. Arrange the Replacement Face Mount Adapter

Plate as shown in Figure 1.

2. Insert the four carriage bolts through the holes in

the Face Mount Adapter Plate and through the
slots in the rigid mount bracket as shown in
Figure 1.

3. Attach nuts loosely to the carriage bolts.
4. Slide the Face Mount Adapter Plate forward

until the carriage bolts are flush against the front
of the slots of the rigid mount Tighten the
carriage nuts firmly to secure the Face Mount
Adapter Plate in place.

36" FF Face Mount Adapter Plate

5/16”
Carriage
Bolts

Tools Required

3/8” Drive 1/2" Socket

3/8” Drive Ratchet

3/8” Drive 9/16 Socket

Flat Head Screwdriver

Installation kit (supplied)

Continued On Back

Figure 1

Face Mount
Adapter

Plate

Figure

2

3/8” Bolts

Mount
Bracket

Prop Side

Back Side

Advertising