Hired-Hand Mega Flow SlantWall Fans: METAL CONE Installation Rev 2-09 User Manual

Mega-flow metal cone, Warning, Installation

Advertising
background image

HIRED-HAND MFG., INC.

• 1733 County Road 68 • Bremen, Alabama 35033 • Phone 256-287-1000 • Fax 256-287-2000

Manual Part No. 4801-5180 Rev 2-09 Page

1

of

2

Arrange panels for assembly
with pilot hole on each panel
facing upward.

Slot for mounting top of
cone to fan housing

Joints

Install #14 x 1/2" sm

screw

Install #14 x 1/2" sm
screw

Pilot hole faces upward

Pull flanges

together to

align

mounting

holes

Mounting
Hole for
Wire Guard





Packing List For One (1) Unit

Tools Required

Four (4) Cone Sections

Four (4) Corner Brackets

7/16 in. (11 mm) Wrench

Ratchet

One (1) Wire Guard

Eight (8) 5/16"-18 x 5/8 Carriage

Bolts

7/16 in. (11 mm) Socket

Marker or Scribe

Five (5) 1/4"-20 Lock Nuts

Ten (10) #14 x 1/2" SIM Screws

Cordless drill and bit (For Installing TEK screws)

Four (4) ¼"-20 x 3/4" Truss

Head Bolts

One (1) Installation Manual

Phillips Head Screwdriver

WARNING!

During Cone Installation Be Sure That Fan Motor Is Not Plugged Into Any Power Source.

Always Double Check Power Sources.


1.

Arrange panels contacting as shown in Figure 1. NOTE: The pilot hole pointing upward. Refer to Figure 1
Inset B.

2.

For each panel, slide panels together. See Figure 1 Inset A.

3.

Align holes of flanges. See Figure 1 Inset A. Install sheet metal screws as shown in Insets B and C.






























!

Assembly & Installation of Cone

MEGA-FLOW METAL CONE

Installation

Mounting Holes for
Damper Ring

Figure 1

Inset A

Figure 1

Inset C

Figure 1:

Inset B