Hired-Hand Emergency Back-Up and Alarms: SCS Curtain Back-up Harness User Manual

Curtain back, Purpose, Directions

Advertising
background image

HIRED-HAND, INC. • 1733 Co Rd 68 • Bremen, AL 35033 • Phone 1-800-642-0123 • Fax 256-287-2000

Part No. 4801-5142




























Purpose

The Back-up Machine Control Harness places a PowerTrak in the ‘open’ position in the event of a
back-up condition of the control panel

Directions

1. Disconnect electrical power from PowerTrak and Controllers.
2. Install the Back-up relay inside the Farm Hand SCS Panel to the left of the power transformer by using

the self-adhesive backing on the relay.

3. On the Controller that is to receive the Back-up Machine Control Harness, disconnect control wires

from the Controller (Common, and OPEN).

4. Connect control wires from the Back-up Machine Control Harness to the controller. Connect Yellow

wire to Common. Connect Brown wire to Open. Refer to diagram.

5. Connect wires having connectors from PowerTrak to Back-up Machine Control Harness. Connect

Yellow wire to Common. Connect Brown wire to Open. Refer to diagram.

6. Replace the four pin harness connecting the Printed Circuit Board (PCB 162 – SCS 16 board) to the

PCB 163 (Back-up board) with one connected to the back-up harness. Refer to diagram.

7. Connect the blue wire to the top of the SCS 16 board labeled Back-up. Connect the blue wire to the

desired cooling Stage.(COOL 1, COOL 2 or COOL 3).

8. Installation

complete.

!!!!

Warning

Curtain Back

Curtain Back

Curtain Back

Curtain Back----up for SCS Panel

up for SCS Panel

up for SCS Panel

up for SCS Panel

PowerTrak

From

PowerTrak

To

Controller

!!!!

Warning

This setup will override main Controller and
open the PowerTrak any time the SCS
Panel is in Back-up operation.

The curtain machine will only open when the

back-up stage connected to it is called for.

J18

J19

J16

G1

R5

J24

J22

J23

ULN2803A

U8

ULN2803A

U5

R21

R22

R20

R28

R29

R30

G2

R6

TZ3

G3

R7

TZ1

R4

ULN2803A

U6

R25

R26

R27

TZ2

J8

J7

J9

J2

R24

R23

J21

J20

J17

J1

J3

R9

R8

ULN2803A

U7

R19

R14

R10

74HCT373

U3

R114

R111
R112

R110

R109

R108

R107

X101

C103

C104

J4

J5

J6

J10

J11

SWX1

R18

R13

R12

R11

R3

R2

R1

C4

X1

C3

C5

PIC16C63

U1

75176

U2

C6

R15

MOV6

MOV5

J25

PIC16C73A

U102

93LC66

U104

C101

MC14489

U105

J105

R106

U103

ULN2803A

75176

U101

C102

J12

J13

J14

J15

74HCT373

U4

Q1

R16

J26

C9

BR3

BR1

C11

AD

J

OU

T

IN

VR4

D22

R

LY104

RLY

101

RL

Y102

RL

Y103

RLY105

J104

J102

J109

R31

R32

J101

J107

R101

R102

R105

J106

J103

R113

R103

R104

J110

J108

D4

D3

D1

D7

CUT-OUT

CUT-OUT

CUT-OUT

CUT-OUT

CUT-OUT

CUT-OUT

RELAY STRIP 1-4

B

.

C

r

i

d

e

r

C

o

p

y

r

i

g

h

t

(

c

)

2

0

0

0

H

i

r

e

d

H

a

n

d

,

I

n

c

.

LOCAL NET ADDRESS

COOL3

COOL2

COOL1

HEAT

BACKUP SYSTEM

HE

AT

CO

OL

3

CO

OL

2

CO

OL

1

BACKUP SYS

TEM

L1

EA

RT

H

AC POWER (

<24 V)

L2

EARTH

L2

L1

AC POWER (<24 V)

NC

+

-

LOCAL NET

NC

-

+

LOCA

L NET

RELAY STRIP 5-8

RELAY STRIP 9-12

RELAY STRIP 13-16

P

C

B

1

6

2

R

e

v

'

A

'

H

i

r

e

d

H

a

n

d

,

I

n

c

.

C

o

p

y

r

i

g

h

t

(

c

)

2

0

0

0

B

.

C

r

i

d

e

r

P

C

B

1

6

3

R

e

v

'

A

'

STATUS LEDs

TRANSMIT

RECIEVE

NORMAL

POWER

BACKUP

ALA

RM

SENSOR

1

SENSOR

2

B

L

A

C

K

C

O

M

W

H

I

T

E

S

E

N

S

O

R

2

E

N

A

B

L

E

O

N

=

E

n

a

b

l

e

d

O

F

F

=

D

i

s

a

b

l

e

d

N

O

N

C

W

H

I

T

E

B

L

A

C

K

SCS 16 Board

Harness

(Common)

(Open)

(Open)

(Common)

Stage Connection

Advertising