INSTALLATION INSTRUCTIONS

MVX-193, MVX-195
MONITOR PANELS

Atlas Sound Monitor Panels are designed to monitor 25 volt or 70.7 volt speaker lines.

The monitor panel as shipped from the factory is wired to monitor 25 volt speaker lines. It is converted
to 70.7 volt operation by cutting the white jumpers across resistors R2 & R5. Resistor R1 is located
on the PC Board attached to the VU meter. Resistor R5 is on the terminal strip located on the sub-
panel.

The VU meter is factory calibrated to read 0dB with a 25 volt peak sine wave input. By removing the jumper
across resistor R1, the meter will read 0dB with a 70 Volt peak input. The meter sensitivity can be field
adjusted by means of the pot (R4) on the VU meter PC Board.

The speaker lines to be monitored are connected to the screw terminals on the back of the panel.
Terminal numbers correspond to the like numbered switch positions. The terminals labeled "SPR" are
spare blank terminals.