SANDPIPER EB1/2-A User Manual

Model eb ½-a, Service and operating manual, Type 2

Advertising
background image

520-069-000 8/00

Model EB½-A Type 2 Page 1

SERVICE AND OPERATING MANUAL

Model EB ½-A

Type 2

WARREN RUPP, INC. A Unit of IDEX Corporation • P.O. Box 1568 • Mansfield, Ohio 44901-1568 USA • (419) 524-8388 Fax (419) 522-7867 • www.warrenrupp.com

PLEASE NOTE!

The photos shown in this manual are for general instruction only. Your specific

model may not be shown. Always refer to the parts list and exploded view drawing for
your specific model when installing, disassembling or servicing your pump.

PRINCIPLE OF PUMP OPERATION

This ball valve pump is powered by compressed air and is a 1:1 pressure ratio

design. It alternately pressurizes the inner side of one diaphragm chamber, while
simultaneously exhausting the other inner chamber. This causes the diaphragms,
which are connected by a common rod, to move endwise. Air pressure is applied
over the entire surface of the diaphragm, while liquid is discharged from the opposite
side. The diaphragm operates under a balanced condition during the discharge
stroke, which allows the unit to be operated at discharge heads over 200 feet (61
meters) of water head.

Since the diaphragms are connected by a common rod, secured by plates to the

center of the diaphragms, one diaphragm performs the discharge stroke, while the
other is pulled to perform the suction stroke in the opposite chamber.

For maximum diaphragm life, keep the pump as close to the liquid being pumped

as possible. Positive suction head in excess of 10 feet of liquid (3.048 meters) may
require a back pressure regulating device. This will maximize diaphragm life.

Alternate pressuring and exhausting of the diaphragm chamber is performed by

means of an externally mounted, pilot operated, four-way spool type air distribution
valve. When the spool shifts to one end of the valve body, inlet air pressure is applied
to one diaphragm chamber and the other diaphragm chamber exhausts. When the
spool shifts to the opposite end of the valve body, the porting of chambers is re-
versed. The air distribution valve spool is moved by an internal pilot valve which
alternately pressurizes one side of the air distribution valve spool, while exhausting
the other side. The pilot valve is shifted at each end of the diaphragm stroke by the
diaphragm plate coming in contact with the end of the pilot valve spool. This pushes
it into position for shifting of the air distribution valve.

The chambers are manifolded together with a suction and discharge check valve

for each chamber, maintaining flow in one direction through the pump.

INSTALLATION & START-UP

Locate the pump as close to the product being pumped as possible, keeping

suction line length and number of fittings to a minimum. Do not reduce line size.

For installations of rigid piping, short flexible sections of hose should be installed

between pump and piping. This reduces vibration and strain to the piping system. A
Warren Rupp Tranquilizer

®

surge suppressor is recommended to further reduce pul-

sation in flow.

This pump was tested at the factory prior to shipment and is ready for operation.

It is completely self-priming from a dry start for suction lifts of 10 feet (3.05 meters) or
less. For suction lifts exceeding 10 feet of liquid, fill the chambers with liquid prior to
priming.

AIR SUPPLY

Air supply pressures cannot exceed 100 psi (6.89 bar). Connect the pump air inlet

to an air supply of sufficient capacity and pressure required for desired performance.
When the air line is solid piping, use a short length of flexible hose, not less than

3

¦

4

"

(19mm) in diameter, between pump and piping to eliminate strain to pipes. Use of a
Warren Rupp Filter/Regulator in the air line is recommended.

AIR INLET & PRIMING

For start-up, open an air valve approximately

1

¦

2

to

3

¦

4

turn. After the unit primes, an

air valve can be opened to increase flow as desired. If opening the valve increases

Air Inlet Capscrews.

IMPORTANT

Read these instructions completely,
before installation and start-up. It is the
responsibility of the purchaser to retain
this manual for reference. Failure to
comply with the recommendations
stated in this manual will damage the
pump, and void factory warranty.

WARNING

Take action to prevent static sparking.
Fire or explosion can result, especially
when handling flammable liquids. The
pump, piping, valves, containers or
other miscellaneous equipment must be
grounded.

BEFORE OPERATION

Before pump operation, inspect all
gasketed fasteners for looseness
caused by gasket creep. Retorque loose
fasteners to prevent leakage. Follow
recommended torques stated in the card
attached to the new pump.

HAZARD WARNING

POSSIBLE EXPLOSION HAZARD can
result if 1, 1, 1,-Trichloroethane,
Methylene Chloride or other
Halogenated Hydrocarbon solvents are
used in pressurized fluid systems
having Aluminum or Galvanized wetted
parts. Death, serious bodily injury and/
or property damage could result.
Consult with the factory if you have
questions concerning Halogenated
Hydrocarbon solvents.

®

Advertising