Options & Accessories

Options & Accessories

Signals

for Switch Mode Units

The number of options per module may be restricted due to limitation of space inside the module or due to a limited number of

connector pins. Potentiometers or interface cards may be supplied separately for installation outside of the module.

General information

pr

input voltage supervision (power ok) incl. relay contacts

A logic signal is given if the input voltage (AC or DC) drops below the specified limit. In
AC input models the rectified input voltage is sensed so that a power fail alarm can be
avoided if at light load mains power returns before the input capacitors are substantially
discharged. A relay contact is provided for failure indication.

dr

output voltage supervision (DC ok) incl. relay contacts

A logic signal is given if the output voltage is below the specified limit. A relay contact is
provided for failure indication.
DC ok level: 5V output: 4,75V
all other voltages: 90% of adjusted voltage

cf

charger / converter fail supervision incl. relay contacts

A logic signal is given if the input voltage, the auxiliary voltage of the primary side and
the current of the primary side exceed or go below a specified range. A relay contact is
provided for failure indication.

ac

AC ok for inverter including relay contacts

A logic signal is given if the output voltage of an inverter is below the specified limit. A
relay contact is provided for failure indication.

IN

L

N

+

-

IN

OUT

IN

OUT

IN

OUT

primary
control
circuit

supervision

Programming

Converter Programming

programming of output voltage from 0 to 100 %

eu1

eu2

eu3

eu4

by external signal, 0 – 10 V

by external signal, 4 – 20 mA

by 270° potentiometer

by 10 turn potentiometer

programming of output current from 0 to 100 %

ei1

ei2

ei3

ei4

by external signal, 0 – 10 V

by external signal, 4 – 20 mA

by 270° potentiometer

by 10 turn potentiometer

iso

isolating amplifier for programming

Programming signal is galvanically isolated from any
potentials of the power supply.

programming via

rs

can

RS232 (external)

CAN Bus (external)

Converter / Charger Monitoring

monitoring of output voltage from 0 to 100 %

mu1

mu2

by external signal, 0 – 10 V

by external signal, 4 – 20 mA

monitoring of output current from 0 to 100 %

mi1

mi2

by external signal, 0 – 10 V

by external signal, 4 – 20 mA

iso

isolating amplifier for monitoring

Monitoring signal is galvanically isolated from any
potentials of the power supply.

monitoring via

rs

can

RS232 (external)

CAN Bus (external)

Charger Programming

temperature features

tc

ts1

ts2

temperature compensated charging voltage
(sensor not included)

temperature sensor not interchangeable due to fixed
resistor values

temperature sensor interchangeable, IC controlled

charging characteristics

ch1

ch2

ch3

External card: automatic and manual selection of charging
characteristic (float/ equalized boost charge) with timer
(delayed return to normal operation), including aux.
supply and options “tc” and “ts1”

External card: consisting of option “ch1” plus: Battery
current limitation & battery shunt

External card: consisting of option “ch2” plus: CAN-Bus-
interface & programmable parameters

Monitoring