Van Air Systems PD-5 Pressure Differential Gauge Kits User Manual

Pd-5, Installation instructions, Warnings

Advertising
background image

WARNINGS

Max Pressure 300 PSIG

PRODUCT PURPOSE & FUNCTION:

Van Air's PD-5 Differential Pressure Indicators provide a visual indication for element

changeout. Designed for F200-55-1/2 thru F200-1000-3 filters, the PD-5 indicator needle will point to
red when a pressure drop of 10 PSID has occurred.

DO NOT INSTALL PD-5 TO EQUIPMENT WHILE UNDER PRESSURE.
FOLLOW INSTRUCTIONS FOR PD-5 WHEN INSTALLING INTO AIR SYSTEM.
DO NOT OPERATE UNIT ABOVE 300 PSIG.
A ZERO DIFFERENTIAL PRESSURE DOES NOT MEAN THAT THE FILTER IS
DEPRESSURIZED. NEVER REMOVE THE INDICATOR AND/OR FILTER
BOWL WITHOUT DEPRESSURIZING THE FILTER HOUSING AND ADJA-
CENT PIPING. FAILURE TO DO SO MAY RESULT IN SERIOUS PERSONAL
INJURY AND/OR DAMAGE TO THE FILTER HOUSING AND/OR INDICATOR.

FIGURE 1 PD-5 KIT DETAILS

INSTALLATION INSTRUCTIONS

PD-5

DIFFERENTIAL PRESSURE INDICATOR KIT

P/N: 84-10001

PD-5

BLANKING

PLATE

O-RING

MOUNTING
SCREWS

DUST

CAP

RED

GREEN

INDICATOR
O-RING

SPECIFICATIONS

MAXIMUM WORKING PRESSURE

300 PSIG

MAXIMUM TEMPERATURE

225°F

MATERIAL

BODY

NYLON 6

LENSES

POLYCARBONATE

SEALS (O-RINGS)

BUNA-NITRILE

MAGNETS

ANISOTROPIC

FERRITE

WEIGHT

3.4 OZ

PRINTED IN THE USA

©2000 VAN AIR SYSTEMS INC.

APRIL 2000

P/N: 432-10001

Advertising