M SERIES DESIGNER FAN-LIGHTS

SAFETY INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the manufacturer.
2. Before servicing or cleaning unit, switch power off at service panel

and lock the service disconnecting means to prevent power from

being switched on accidentally. When the service disconnecting

means cannot be locked, securely fasten a prominent warning device,

such as a tag, to the service panel.

3. Installation work and electrical wiring must be done by qualified

person(s) in accordance with all applicable codes and standards,

including fire-rated construction.

4. Sufficient air is needed for proper combustion and exhausting of

gases through the flue (chimney) of fuel burning equipment to prevent

back drafting. Follow the heating equipment manufacturer's

guideline and safety standards such as those published by the

National Fire Protection Association (NFPA) and the American Society

of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE)

or local code authorities.

5. When cutting or drilling into wall or ceiling, do not damage electrical

wiring and other hidden utilities.

6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be marked

as appropriate for the application and be connected to a GFCI

(Ground Fault Circuit Interrupter) – protected branch circuit.

8. NEVER place a switch where it can be reached from a tub or shower.
CAUTION: FOR GENERAL VENTILATING USE ONLY!
Do Not Use To Exhaust Hazardous Or Explosive Materials Or Vapors.

• Screwdriver
• Hammer
• Electric drill

• Wire nuts
• Safety glasses
• Ruler or
straight edge

• Keyhole saw or
jig saw
• Wire cutters
• Wire stripper

TOOLS FOR INSTALLATION:

The Nuvent Designer Fan-Lights listed in these instructions are designed

for use in the bathroom. Approved for installation above a tub or

shower enclosure when connected to a UL Listed GFCI protected branch

circuit. Not for use in kitchen.

NEW CONSTRUCTION: When installing this product in new

construction the housing should be mounted with wiring and duct

during the rough-in phase. The blower unit and dome light should be

installed after the ceiling is finished.

EXISTING CONSTRUCTION: Installation for existing construction

requires access above or behind planned installation location.

WIRING: This product requires 120v AC standard house wiring (with

ground) from the power source through a standard wall switch

(switches) to the unit's housing. NuVent switch model R2SW can be

ordered separately for use with this unit.

DUCTING: For best performance use the following guidelines when

planning for the installation of duct work for this unit:

1. Use correct duct size as indicated in installation instructions. (Step 8)

2. Ducting should run from the fan to the outside of the home or

building. The duct run should be as short and as straight as

possible.

3. Identify the ducting requirements per local/municipal code.

4. When using flexible duct, avoid kinks and always expand the

ducting as fully as possible.

PLANNING

INSTALACIÓN

1. Remove blower assembly before installing housing. Remove screw

from blower assembly then slide assembly sideways and lift out. (Fig. 1)

INSTALLATION IN NEW CONSTRUCTION

2. Attach housing to joist through keyhole mounting tabs (Fig. 2) or

adjustable hanger bars (Fig. 3) using nails or screws. (Do not

tighten.) Adjust the housing so it will not extend past the finished

ceiling. The outer edge of the housing should be recessed 1/8" to

1/4" from the finished ceiling.

3. Once housing is correctly positioned, it is important to tighten

screws or add additional nails to hold fan housing firmly in

position. This prevents vibration and noise.

WIRING

Turn off electrical power at service panel.

4. Remove screw that holds electrical box cover. (Fig. 4)

5. Run 120v AC wiring with ground from the wall switch (switches) to

the fan electrical box.

6. Remove one (two) of the electrical knockouts from the fan and pull

supply wiring into the electrical box.

INSTALLATION

FIGURE 4

FIGURE 3

FIGURE 2