AW Gear Meters CAPM-2N User Manual

Capm-2n carrier frequency pickup module

Advertising
background image

AW Gear Meters 8809 Industrial Drive, Franksville, WI 53126   web: www.awgearmeters.com 

 Tel:  262‐884‐9800  Fax:  262‐884‐9810  Email: awinfo@aw‐lake.com          

REV. 10/01                                                                                                                                         CAPM‐2N.DOC

CAPM-2N Carrier Frequency Pickup Module


Description:

The CAPM-2N is used with the HPM series and the TR series of flow meters. The CAPM-2N is a
Carrier Frequency sensor which means there is no permanent magnet in the pickup and any
magnetic drag on the flow meter gears or turbine is avoided. The CAPM-2N requires a supply voltage
between 10 Volt DC to 30 Volt DC. A diode in the supply input prevents damage to the module in
case the polarity of the supply voltage is wrong. The output signal is a square wave. The frequency is
proportional to the flow rate.


The output is a sinking open collector NPT transistor.


Technical Data

:

Supply Voltage

:

10 to 30 Volt DC

Supply Current

:

9 mA @ 15 Volt, Max 18mA

Minimum Signal

:

0.5 Hz

Duty Cycle :

50%

Frequency Output : Flow dependent, up to 2000 Hz
Sinking Capacity: 50 mA Max
Temperature Range:

-60 F to 185 F (-50 C to 85 C)





Connections:
A -

+10 to 30 Volt DC supply voltage

B -

Ground for supply and signals

C -

Frequency signal output


AW Company wire color code:
Supply Voltage:

Red

Ground: Black
Signal: White



Advertising