Quad-80

Technical Data Guide


Description:


The Quad-80 is an advanced, multi -option sensor used only with the JV-80KL & JV-90KL flow meter. This

sensor has several jumper selectable outputs to either multiply the pulse count or to change the

amplitude of the pulse. The pulse multiples include 1X, 2X, and 4X. Signal amplitude options are:
(supply - 1.4V) or 5V TTL compatible. This sensor also features quadrature output which allows for dual

pulse counting by separate data gathering devices or for determining flow direction.


Technical Data

Supply Voltage:

12 - 27Vdc

Supply Current:

70mA

Temperature Range:

-40F to +185F

Signal Output:

Sourcing, square wave frequency (sinking version available) NPN type.

Output low

0V

Output high

Supply - 1.4V or 5V (jumper selectable)

50% duty cycle

Flow dependent, 1500Hz max.

Signal 1 can be set for X4, X2 or X1 frequency output. Signal 2 can be set for X2 or X1 frequency output. Quadrature

output for flow direction is obtained with signals 1 and 2 set in the X1 or X2 output mode.


Note:
Output signal has in-line diode protection. Once connected to readout, if signal does not go to ground, connect an

external resistor, 5K-10Kohm, between input and ground of monitoring equipment.

Jumper settings



*default See page 2 for Quad-80 Maintenance Guide

Connector pin out

Red

1 12-27vdc supply

Black

2 Ground

White

3 Signal 1

Green

4 Signal 2

Signal 1 output

J2

J4 Output

A or B A

X4

A*

B

X2

B

B

Single

Output signal amplitude

J1

Output

A*

Supply - 1.4v

B

+5v

Signal 2 output

J3

Output

A*

X2

B

Single