HT instruments SOLAR300N User Manual

Page 102

Advertising
background image

SOLAR300 - SOLAR300N

EN - 100

Description of the columns:

N.:

Progressive spike number.

L.:

Phase in which the spike occurred.

Time:

Date/time in which the anomaly occurred.

Peak+:

Max. positive value reached by the spike during the observation
interval.

Peak-:

Min. negative value reached by the spike during the observation
interval.

Delta+:

Max. relative positive differential reached by the spike during the
observation interval.

Delta-:

Min. relative negative differential reached by the spike during the
observation interval.

Type:

Spike type (Up/Down).

F/S:

Spike speed (Fast if dV/dt >100V/5

s, Slow if dV/dt >100V/78s).

Within this page, the following keys are active:
 The up and down arrow keys move the cursor along the list of Spikes

 The right and left arrow keys move the column display to the right or to the left

 The

F1 key (or the PAG item on the display) moves to the following pages of Spikes (to be

selected with the F3 or F4 key or with the MOD (+) or MOD (-) items on the display)

 The

F2 key (or the PARAM item on the display) accesses the page which shows the

settings made for the Spikes (see Fig. 163)

 The

ESC key (or the smart icon ) exits the function and goes back to the “Recording

Analysis” page (see Fig. 154)

This page shows the parameters set for voltage Spikes before recording:

Fig. 163: Spikes parameters


The following elements are indicated:

Limit: set voltage threshold.
The total number of spikes occurred is also displayed (Events)

Within this page, the following keys are active:
 The up and down arrow keys move the cursor alternately onto Type, Phase or F/S

 The

F3 and F4 keys (or the item MOD (+) and MOD (-) on the display) allow filtering

the Spikes to be selected. It is possible to select All, Up, Down (if the cursor highlights
Type); All, Phase1, Phase2, Phase3, Neutral (if the cursor highlights Phase); All,
Fast, Slow (if the cursor highlights F/S)

 The

ENTER key (or the smart icon

on the display) confirms the choice previously made

and displays the Voltage Spike table

 The

ESC key (or the smart icon ) exits the function and goes back to the “Spikes”

page (see Fig. 162)

Advertising