5.7.1.8. Analysis of producted energy
This page shows the Energy and Peak power values producted while recording

25/01/2013 – 16:55:10

TOT. ENERGY PRODUCTION – Pag x/y

Eact =

15

Wh

Ppeak =

1.31

kW

Date Ppeak

:

21/01/13 16:45:00

Start rec.

:

21/01/13 16:45:00

Stop rec.

:

21/01/13 18:00:00

Rec. Time

:

00d 1h 15m

Int. Per.

:

15m

PAGE

SCOPE

HARM

VECTORS

Fig. 171: Screen of total producted energy

Description of the displayed values:

Eact:

Total active power produced while Recording.

Ppeak:

Max. active power peak (measured on 16 periods of mains frequency)
produced while recording

Date Ppeak: Date and time in which the power peak occurred
Start rec.:

Starting date of the recording

Stop rec.:

Stopping date of the recording

Rec. Time Recording time expressed in days (d), hours (h) and minutes (m)
Int. Per.:

Set integration period value

CAUTION

The Total Produced Energy page is shown only if general parameter Total
“Active Power & Energy” has been recorded (see § 5.4.2.7) and if the
recording parameter “Co-generation” has been enabled (see § 5.4.2.5).