HT instruments SOLAR300N User Manual

Page 21

Advertising
background image

SOLAR300 - SOLAR300N

EN - 19

5.2.3.1. Multi-MPPT photovoltaic system screen – Single-phase output
When SOLAR300N is in connection with MPP300, the display shows the following
parameters:



DC



PV





AC

PARAMETER CAPTION:
PRp:

 Performance Ratio (ref. active powers)

Pdc

 Inverter input DC power

DC

 Photovoltaic panel performance

Pac

 Inverter output AC power

AC

 Inverter performance

Pnom

 Photovoltaic system rated power

If the remote unit SOLAR-02 is connected to the
MPP300, the following values are also available:
Irr

 Solar irradiation

Tpv

 Default photovoltaic panel temperature

Tenv

 Default environmental temperature

When Tenv or Tpv values are displayed in blue, it
means that these values are different from the
default ones, as those measured by SOLAR-02
are not available (see § 5.3.2.4)

Fig. 21: Multi-MPPT photovoltaic system screen – Single-phase output


Pressing the F3 (DC) key displays the following screen:




PARAMETER CAPTION:

Vdcx

 Inverter input DC voltage

Idcx

 Inverter input DC current

Pdcx

 Inverter input DC power


x=1,2,3 according to the number of MPPTs set

Fig. 22: Multi-MPPT photovoltaic system DC screen – Single-phase output


Pressing the F4 (AC) key displays the following screen:




PARAMETER CAPTION:

Vac1

 Inverter output phase-neutral AC voltage

Iac1

 Inverter output AC phase current

Pac1

 Inverter output AC power


Fig. 23: Multi-MPPT photovoltaic system AC screen – Single-phase output

Advertising
This manual is related to the following products: