Precautions and safety measures, Caution – HT instruments SOLAR300N User Manual

Page 6

Advertising
background image

SOLAR300 - SOLAR300N

EN - 4

1. PRECAUTIONS AND SAFETY MEASURES

1.1. GENERAL
This meter has been designed in compliance to IEC/EN61010-1 directive. For your own
safety and to avoid damaging the instrument we suggest you follow the procedures hereby
prescribed and to read carefully all the notes preceded by the symbol


Before and during measurements please take care of below points:
 The instrument consists in a main unit SOLAR300 or SOLAR300N and a remote unit

for acquisition (SOLAR-01 or SOLAR-02 generically called “SOLAR-0x except notation
specifically indicated”). If not otherwise indicated, all safety instructions are intended as
always referred to the main unit.

 Do not measure voltage or current in wet or dusty places.

 Do not measure in presence of gas, explosive materials or combustibles.

 Do not touch the circuit under test if no measurement is being taken.

 Do not touch exposed metal parts, unused terminals, circuits and so on.

 Do not use the meter if it seems to be malfunctioning (i.e. if you notice deformations,

breaks, leakage of substances, absence of messages on the display and so on).

The below symbols are used in this manual and on meter:

Caution: keep to what prescribed by the manual. An incorrect use could damage
the instrument or its components

High voltage: risk of electric shock

Double insulation

Ground reference


1.2. PRELIMINARY

INSTRUCTIONS

 This instrument has been designed for use in places with pollution class 2.

 It can be used for Voltage and Current measurements on installations of excess

voltage category IV 600V to earth and a 1000V maximum voltage between inputs.

 Please keep to the usual safety standards aimed at ptrotecting against dangerous

currents and protecting the instrument against incorrect operations.

 Only the accessories supplied with the instrument guarantee compliance with the

safety standards. Accordingly, they must be in good conditions and, if necessary, they
must be replaced with identical models.

 Do not take measurements on circuits exceeding the specified current and voltage

limits.

 Before connecting cables, crocodiles and clamps to the circuit under test, make sure

that the right function has been selected.

CAUTION

 Please perform a complete charging of internal battery for at least 5 hours

before using the meter the first time.

 Please press and hold the ON/OFF key for about 5s when turning on the

meter the first time.