Caution – HT instruments VEGA78 User Manual

Page 59

Advertising
background image

VEGA78

EN - 57

DEFAULT CONFIGURATION

MENU GENERAL

PARAMETER

SETTINGS

Analyzer Settings

System 4-wire

Freq[Hz] 50

Clamp Type

FLEX

FS Clamp[A]

3000

VT Ratio

1

Analyzer Settings
Advanced

Zoom Graphics

AUTO

Harm. Type

ALL

Harm. Values

ABSOLUTES

Zoom 1st Harm.

YES

Average Values

NO

Recording Settings

Comments DEFAULT

Start Manu

Stop Manu

Integration period

15min

Cogeneration OFF

General Parameters

V1N,V2N,V3N,VN-PE,V12,V23,V31,

I1, I2, I3, IN, Hz

Pt, P1,P2,P3, Qti, Qi1, Qi2, Qi3, Qtc, Qc1,

Qc2, Qc3, St, S1, S2, S3, Pft, Pft1, Pft2, Pft3,

Cosphit, Cosphi1, Cosphi2, Cosphi3, Eat,

Ea1, Ea2, Ea3, Erit, Eri1, Eri2, Eri3, Erct,

Erc1, Erc2, Erc3

Voltage harmonics

THD, DC, h1, h2, h3…h11

Current harmonics

THD, DC, h1, h2, h3…h11

Voltage anomalies

ON

Ref. Voltage anomalies

230V

Up threshold anomalies

+6%

Down threshold anomalies

-10%

Unbalance ON

Table 10: Parameters of default configuration

CAUTION

The DEFAULT configuration defines the selection of parameters on meter
from the factory, as shown in Table 10. Each new modification performed
and saved by the user on “Analyser Settings” section replaces this
configuration with new selection which can be different from the default
standard.