KYORITSU 8006 User Manual

Model 8006, Instruction manual clamp adaptor, Features

Advertising
background image

INSTRUCTION MANUAL CLAMP ADAPTOR

Model 8006

1. Features

・ Clamp adaptor designed to measure AC current up to 1,500A.
・ Can accommodate up to 60mm-dia conductor or 50mm by 75mm bus-bar.

2.Specifications 3.Designations

Measuring range

0~1,500A AC

Accuracy

0~1,000A AC

±3%rdg±1A

1,000A~1,500A AC

±5%rdg

Output Voltage

0~1.5V AC against 0~1,500A AC

Load Resistance

More than 1kΩ

Allowable

Measurement

0~600A continuous

600~1,000A 30 minutes max.

Time

1,000~1,500A 5 minutes max.

Output Leads

2m long with 4mm-dia banana plugs

Frequency Range

45 Hz~65Hz

Dimensions

240(L) × 85(W) × 30(D)mm

Weight Approx.500g

Conductor Size

60mm max. Outside diameter or

50mm × 75 mm (bus-bar)

4.Operating Instructions

① Transformer Jaws
② Trigger
③ Output Leads


4.1 Preparation for Measurement
Connect output leads to an AC voltmeter.
The output voltage of the clamp adaptor is 1.5V against 1,500A Input current.
Select an appropriate range of voltmeter in accordance with the current to be measured.

4.2 AC Current Measurement
Press the trigger to open the transformer jaw and clamp on a conductor.
Take the reading of the voltmeter and convert it into amperage.
For example, the reading and measured value will be as follows when the 0 to 2V range
of a digital multi meter is used:
Reading of Digital Multimeter Measured Value

1.200V 1,200A

Be careful about the fact that the transformer jaws with overheat when continuous measurements are made
of 600 to 1,000A for more than 30 minutes or 1,000 to 1,500A for more than 5 minutes.

Kyoritsu reserves the right to change specifications or

designs described in this manual without notice and without.