ROTRONIC AC3021 User Manual

Unit

Advertising
background image

12

.0

94

5.0

00

2

12

.0

94

5.0

00

2

ROTRONIC AG, CH-8303 Bassersdorf

Tel. +41 44 838 11 44, www.rotronic.com

ROTRONIC Messgeräte GmbH, D-76275 Ettlingen

Tel. +49 7243 383 250, Fax +49 7243 383 260, www.rotronic.de

ROTRONIC SARL, 56, F - 77183 Croissy Beaubourg

Tél. +33 1 60 95 07 10, www.rotronic.fr
ROTRONIC Italia srl

,

I- 20157 Milano

Tel. +39 2 39 00 71 90, Fax (+39) 02 33 27 62 99, www.rotronic.it

ROTRONIC Instruments (UK) Ltd, Crompton Fields,

Phone +44 1293 571000, www.rotronic.co.uk

ROTRONIC Instrument Corp, NY 11788, USA

Phone +1 631 427-3898, www.rotronic-usa.com

ROTRONIC South East Asia Pte Ltd, Singapore 339156

Phone +65 6294 6065, www.rotronic.com.sg

ROTRONIC Shanghai Rep. Office, Shanghai 200233, China

Phone +86 40 08162018, www.rotronic.cn

ROTRONIC AG, CH-8303 Bassersdorf

Tel. +41 44 838 11 44, www.rotronic.com

ROTRONIC Messgeräte GmbH, D-76275 Ettlingen

Tel. +49 7243 383 250, Fax +49 7243 383 260, www.rotronic.de

ROTRONIC SARL, 56, F - 77183 Croissy Beaubourg

Tél. +33 1 60 95 07 10, www.rotronic.fr
ROTRONIC Italia srl

,

I- 20157 Milano

Tel. +39 2 39 00 71 90, Fax (+39) 02 33 27 62 99, www.rotronic.it

ROTRONIC Instruments (UK) Ltd, Crompton Fields,

Phone +44 1293 571000, www.rotronic.co.uk

ROTRONIC Instrument Corp, NY 11788, USA

Phone +1 631 427-3898, www.rotronic-usa.com

ROTRONIC South East Asia Pte Ltd, Singapore 339156

Phone +65 6294 6065, www.rotronic.com.sg

ROTRONIC Shanghai Rep. Office, Shanghai 200233, China

Phone +86 40 08162018, www.rotronic.cn

Bitte lesen Sie diese Kurzanleitung genau durch, bevor Sie die Box installieren.

Allgemeine Beschreibung

Die Verteilerbox AC3021 wurde entwickelt um in ein RS-485 Netzwerk einzubinden und
eine möglichst einfache und schnelle Installation zu gewährleisten.

Montage
Die Verteilerbox wird mit den mitgelieferten Schrauben an eine Wand montiert.
Ablauf: Bohren Sie zwei Löcher in einem Abstand von 90mm. Setzen Sie die beiden mitgelie-
ferten Dübel ein. Befestigen Sie nun mit den beiden Schauben die Verteilerbox an die Wand.

Kabeleinführung
Die Verteilerbox bietet insgesamt 8 Kabeleinführungen. Stechen Sie mit einer Aale in die Vor-
markierten Kabeleinführungen um eine genügend grosse Öffnung für das Kabel zu erhalten.
Stossen Sie nun das Kabel durch das Loch und schliessen es an der gewünschten Klemme an.

Please read these short instructions carefully before installing the box.

General Description

The junction box AC3021 was designed to simplify RS-485 networks and guarantees a quick
and easy installation.

Installation
The junction box can be mounted with the delivered screws on a wall.
Procedure: Drill two holes at a distance of 90mm. Insert the supplied wall plugs. Fix the
junction box to the wall with the two screws.

Cabling
The junction box offers a total of 8 cable entries. Enlarge the marked cable entries with an
awl in order to get a large enough opening for the cable. Push the cable through the hole
and connect it to the terminal block.

KURZBEDIENUNGSANLEITUNG

SHORT INSTRUCTION MANUAL

VERTEILER-BOX AC3021

DISTIRIBUTON BOX AC3021

Elektrische Installation und Anschlüsse

Electrical installation and connections

O

UT

P

UT

Block

Designation

K1-1

V +

K1-2

GND

K1-3

D +

K1-4

D

K3-1

Shield

K3-2

Shield

K2-1

V +

K2-2

GND

K2-3

D +

K2-4

D

K4-1

Shield

K4-2

Shield

AUS

GA

N

G

Block

Bezeichnung

K1-1

V +

K1-2

GND

K1-3

D +

K1-4

D

K3-1

Schirm

K3-2

Schirm

K2-1

V +

K2-2

GND

K2-3

D +

K2-4

D

K4-1

Schirm

K4-2

Schirm

INP

U

T

Block

Designation

K6-1

V +

K6-2

GND

K6-3

D +

K6-4

D

K6-5

Shield

K6-6

Shield

K5-1

Shield

K5-2

EING

ANG

Block

Bezeichnung

K6-1

V +

K6-2

GND

K6-3

D +

K6-4

D

K6-5

Schirm

K6-6

Schirm

K5-1

Schirm

K5-2

K 1

K 2

1
2
3
4

1
2
3
4

K5

1
2

K 3

2 1

1

2

3

4

5

6

K 4

2 1

B1

K 6

K 1

K 2

1
2
3
4

1
2
3
4

K5

1
2

K 3

2 1

1

2

3

4

5

6

K 4

2 1

B1

K 6

Note
B1: For a termination (end box) please close
the jumper on the PCB.

Hinweis
B1: Für eine Terminierung (End Dose) schlies-
sen Sie den Jumper auf der Printplatte an.

Example of an RS-485 network with HF8 Transmitters

Beispiel eines RS-485 Netzwerk mit HygroFlex8 Messumformer

HF8

AC3021

AC3021

AC3021

Ethernet

HF8

K3:4

K3:3

K3:2

K3:1

AC3021

GND

D+

D-

T

V+

GND

D+

D-

V+

T

T

T

GND

D+

D-

V+

GND

D+

D-

V+

GND D+ D-

V+

PC

~

GND D+ D-

V+

Unit

GND D+ D-

V+

GND

V+

D+

D-

Shield

D-

D+

GND

AC3021

V+

AC3021

Shield

D-

D+

GND

Shield

D-

D+

GND

AC3021

Shield

D-

D+

GND

V+

AC3021

Master

AC3011

Shield

D-

D+

GND

V+

Slave

HF5

Shield

D-

D+

GND

V+

Slave

HF5

Shield

D-

D+

GND

V+

Slave

HF5

Shield

D-

D+

GND

V+

V+

V+

Power supply 1 V+

GND

Power supply 2 V+

GND

V+ not wired

100m

1000m

PC

with

HW4

Ethernet

Advertising