EL110 SERIES CABINET LOCK

INSTALLATION INSTRUCTIONS

DRAWINGS NOT TO SCALE. INFORMATION IN THIS DATASHEET MAY BE CHANGED WITHOUT NOTICE.

An ASSA ABLOY Group brand

IMPORTANT NOTE: Lock is designed to be fi tted into cabinets and lockers etc with swing or sliding doors.

Lock is supplied in “Power-to-Open” confi guration as the initial factory setting.

Striker may engage with lock from side or front.
Front Enagement : see Fig.1
Side Engagement : see Fig.2

Mount lock on inside of cabinet, connect wiring (see Electrical Specifi cation) and power up lock. Lock and striker
dimensions are shown in Fig.3. Allow suffi cient space betwen lock unit and cut-out for wires as bunching of wires
may cause unit to malfunction.

Adjust the striker horizontally and vertically to ensure the striker locking recess engages with locking pin in the
lock.

Open and close the door several times, and readjust striker if necessary to achieve a smooth closing operation.

Confi gure lock mode of operation (see Fig.4). Lock may need to be removed temporarily to be reconfi gured.

When lock and striker is in place, remove fi lm from double-sided tape on solenoid and affi x faceplate onto lock.

1.

2.

3.

4.

5.

6.

ELECTRICAL SPECIFICATIONS

Solenoid Leads Colour

Red

Blue

Black

Supply Voltage

12 VDC
24 VDC
48 VDC

Current Draw

175 mA

88 mA
45 mA

CAUTION!

Incorrect supply voltage may cause damage not cov-

ered by warranty. Please check supply voltage with a suitable meter
to ensure it is within +/- 15% of the nominal voltage shown above
with the strike powered.

This product has been designed for use in weather protected areas
only. DO NOT OIL OR LUBRICATE.

Fig. 3 - Lock and Strike Dimensions

18

39.9

31

R4

4.5mm Horizontal
Adjustment

22.5

5mm Sliding
Vertical Adjustment

55

13.5

21.5

30

72.7

28

Fig. 1 - Front Engagement

37

To prevent over- or
under-travel, set
distance between
back mounting face
of lock and striker
to 37mm.

Striker

Lock

Fig. 2 - Side Engagement

11

To prevent over- or
under-travel, set
distance between
back mounting face of
striker and centre of
nearest fi xing hole of
lock to 11mm.

Lock

Striker

Fig. 4 - Changing Mode of Lock Operation

Remove two rear solenoid fi xing screws.
Remove solenoid, spring and wire.
Confi gure solenoid, spring and wire depending on the
lock mode required, as shown below.



For Power-to-Lock (Fail Safe), reinsert using the
two lower solenoid fi xing screw holes.

For Power-to-Open (Fail Secure), reinsert using
the two upper solenoid fi xing screw holes.

Wire

Long Spring

Short Spring

Power-to-Lock

(Fail Safe)

Power-to-Open

(Fail Secure)

Advertising