UEi Test Instruments UTLIR2 User Manual

Utlir2, Caution, Infrared ther mometer

Advertising
background image

˚C/˚F

MAX

HOLD ˚F

UTLIR2

Instruction Manual

Infrared

Ther

mometer

Backlit LCD Screen

Mode Key

Infrared Lens

Laser

Trigger

Battery Cover

The UTLIR2 infrared thermometer makes it easy to check the

temperature of vents, various rooms, motor bearings, power

panels and fuses, and an amazing variety of other applications.

It includes laser sighting to help identify your temperature

target. CE listed.

Features:

Default Screen

Instructions

1. Simply aim the thermometer at the measure target with Lens and

press trigger to display the surface temperature.

2. During the measurement, the MAX reading will be displayed

beside the icon.

3. The Distance: Spot is 10:1. Please make sure the target area is

within the field of view.

MODE: Press Mode Button to change from F˚ to C˚.

BACKLIGHT: Backlight is always on

LASER: Class II Laser: always enabled while measuring.

CAUTION

WHEN DEVICE IS IN USE, DO NOT LOOK DIRECTLY INTO THE

LASER BEAM–PERMANENT EYE DAMAGE MAY RESULT.

USE EXTREME CAUTION WHEN OPERATING THE LASER.

NEVER POINT THE DEVICE TOWARDS ANYONE’S EYES.

KEEP OUT OF REACH OF ALL CHILDREN.

Measurement Range

-36.4~689˚F (-38~365˚C)

Operating range

32˚ to 122˚F

Accuracy

(obj = 59˚~95˚F/amb = 77˚F)

± 2.7˚F

Accuracy

(amb = 73˚F ± 4˚)

obj =

-31˚ to 32˚F

±(4.5˚F + 0.05/degree)

obj =

32˚ to 685˚F ±2.5% of reading or 4.5˚F

(whichever is greater)

Emissivity

0.95 Fixed

Resolution

0.5˚F

Response Time

<1 sec

Distance:Spot

10:1

Battery life

14 hours

Specifications

UTLIR2

Limited Warranty

Infrared

Ther

mometer

The UTLIR2 is warranted to be free from defects in

materials and workmanship for a period of one year from the date

of purchase. If within the warranty period your instrument should

become inoperative from such defects, the unit will be repaired

or replaced at UEi’s option. This warranty covers normal use and

does not cover damage which occurs in shipment or failure which

results from alteration, tampering, accident, misuse, abuse, neglect

or improper maintenance. Batteries and consequential damage

resulting from failed batteries are not covered by warranty.

Any implied warranties, including but not limited to implied

warranties of merchantability and fitness for a particular purpose,

are limited to the express warranty. UEi shall not be liable for

loss of use of the instrument or other incidental or consequential

damages, expenses, or economic loss, or for any claim or claims

for such damage, expenses or economic loss. A purchase receipt

or other proof of original purchase date will be required before

warranty repairs will be rendered. Instruments out of warranty will

be repaired (when repairable) for a service charge. Return the unit

postage paid and insured to:

Attn: UEi Service

8030 SW Nimbus Ave.

Beaverton, OR 97008

1-800-547-5740 • FAX: (503) 643-6322

www.ueitest.com • Email: [email protected]

This warranty gives you specific legal rights. You may also have

other rights which vary from state to state.

Please

Recycle

Storage & Cleaning

The sensor lens is the most delicate part of the thermometer. The lens should

be kept clean at all times, care should be taken when cleaning the lens using

only a soft cloth or cotton swab with water or medical alcohol. Allowing the

lens to fully dry before using the thermometer. Do not submerge any part of the

thermometer. The thermometer should be stored at room temperature between

–20 to +65°C (-4~149°F).

Error Messages

‘Hi’ or ’Lo’ is displayed when the temperature being

measured is outside of the measurement range.

‘Er2’ is displayed when the thermometer is exposed to

rapid changes in the ambient temperature.

‘Er3’ is displayed when the ambient temperature

exceeds 32°F (0˚C) or + 122°F (50˚C). The thermometer

should be allowed plenty of time (minimum 30 minutes)

to stabilize to the working/room temperature.

Error 5~9, for all other error messages it is necessary to

reset the thermometer. To reset it, turn the instrument

off, remove the battery and wait for a minimum of

one minute, reinsert the battery and turn on. If the

error message remains please contact the Service

Department for further assistance.

Batteries

 

 

 