Cleaning the corona wire

4

If you have print quality problems, clean the corona wire as follows:

a

Open the front cover and leave the machine for at least 10 minutes to cool down.

b

Take out the drum unit and toner cartridge assembly.

IMPORTANT

• We recommend that you put the drum unit and toner cartridge assembly on a piece of disposable paper

or cloth in case you accidentally spill or scatter toner.

• To prevent damage to the machine from static electricity, DO NOT touch the electrodes shown in the

illustration.