AltiGen comm TRITON T1 User Manual

Triton t1 board

Advertising
background image

TRITON T1 BOARD

Q

U I C K

I

N S TA L L AT I O N

G

U I D E

M

INIMUM

S

YSTEM

R

EQUIREMENTS

:

• IBM/PC AT compatible system with adequate number of full-size ISA and PCI slots
• 233 Mhz Pentium processor (or better)
• 2 - 4 GB Hard Disk Drive Space (depending on voicemail requirements)
• Windows NT Server 4.0 with Service Pack 4 (or higher) installed
• 128 MB RAM
• AltiGen’s Quantum Telephony Board (one or more, Rev. D or higher)
• AltiGen’s Triton T1 Board (one or more)
• AltiWare OE R3.0 (or higher)
• 300W/10A CPU Power (minimum required to power AltiGen boards only)
• CSU (Channel Service Unit)

*** Faulty signals include the following: yellow alarm, bipolar violation or frame error

MVIP BUS

Termination Switch

MVIP Connector

TRITON T1 BOARD

System

Configuration Switch

# of AltiGen Boards

# of Slots**

CPU

HDD

1 Triton T1, 1-3 Quantum

2 PCI, 3 ISA

233 Mhz

2GB

1 Triton T1, 1-6 Quantum

2 PCI, 6 ISA

300 Mhz

2GB

1-4 Triton T1, 1-10 Quantum 5 PCI, 10 ISA

350 Mhz

4GB

# of AltiGen Boards

Power Supply**

Typical Power Supply

1 Triton T1, 1-3 Quantum

+12V: 4.2 Amps +5V: 6Amps

300W/30A@5V/12A@12V

1 Triton T1, 1-6 Quantum

+12V: 8.4 Amps +5V: 10.8Amps

400W/40A@5V/16A@12V

1-4 Triton T1, 1-10 Quantum +12V: 14 Amps +5V: 21Amps

400W/40A@5V/16A@12V

GREEN LED

RED LED

Status

OFF

OFF

No power

ON

OFF

Normal operation

OFF

ON

No signal

ON

Flashing

Faulty signal with frame synchronization***

OFF

Flashing Faulty signal without frame synchronization

Alternating

Alternating

Frame slips in normal operation

The Triton T1 Board uses the following signaling and framing features:

Signaling: loop start, ground start, E&M immediate start, E&M wink start*

Line Encoding: AMI, B8ZS*

*recommended

** The above system requirements are for AltiGen components only, and do not take into account requirements for other

system components such as motherboard, disk drives, etc.

LED Indicators