Troubleshooting

Symptom

Possible Cause

Action

Erratic behavior.

Unit not receiving enough
power under self-powered
operation.

Use the Power Adapter that was supplied with the

unit to provide

Pressing the
Hotkeys gets no
response.

The connection from the
selected port to the target
computer has been
broken, or the computer is
turned OFF.

Check the Online LED for the selected port. If it is not
lit:
1. Manually press one of the Select switches to

connect to a computer that is powered ON.

2. Check the cables to make sure they are all

properly connected.

Improper keyboard
reset.

1. Reset the keyboard (and mouse) by

simultaneously pressing Buttons 1 and 2 on
the First Stage unit for 3 seconds.

2. Unplug the keyboard connector from the

Console Keyboard Port, then plug it back in.

Improper Master View
reset.

Turn off all Master View units and wait five seconds
before turning them back on. See Powering Off and
Restarting, p. 12, for details.

Incorrectly keying in the
Port ID.

After invoking the Hotkey function with the [Numlock
/] combination, be sure to key in the Port ID and press
[Enter] within one second for each key.

Mouse is not
responding.

Improper mouse reset.

1. Reset the mouse (and keyboard) by
simultaneously pressing Buttons 1 and 2 on

the First Stage unit for 3 seconds.

2. Unplug the mouse connector from the

Console Mouse Port, then plug it back in.

2005-12-21