service data sheet

240389641

ice & Water - aUtOMatic deFrOst

side BY side - r134a

iMpOrtant saFetY nOte

The information provided herein is designed to assist qualified
repair personnel only. Untrained persons should not attempt to
make repairs due to the possibility of electrical shock. Disconnect
power cord before servicing this appliance.
iMpOrtant
If any green grounding wires are removed during servicing,
they must be returned to their original position and properly
secured.

caUtiOn

all electrical parts and wiring must be shielded from torch
flame. dO nOt allow torch to touch insulation; it will char
at 200°F and flash ignite (burn) at 500°F. excessive heat will
distort the plastic liner.

nOte

This product comes equipped with an Adaptive Defrost Control
(ADC). To activate manual defrost, simultaneously press and
hold the Fresh Food up (+) and Fresh Food down (-) keys for 5
seconds. A “d” in the freezer temperature window and “F” in the
refrigerator temperature window will display when the heater is
activated. To deactivate manual defrost, simultaneously press
and hold the Fresh Food up (+) and Fresh Food down (-) keys
for 5 seconds. A “d” and “F” will be displayed until the defrost
cycle is complete.

ice Maker inFOrMatiOn

test cycling

Press the momemtary contact on the ON/OFF switch
for approximately 15 seconds. Ice maker will continue to
complete the cycle.

Water Fill volume

Remove cover by inserting screwdriver in notch at bottom and
prying cover from housing. The water fill adjustment screw
will change the fill time. One turn is equal to 20cc (.68 oz.).
The correct fill is 102 to 110cc (3.25 to 3.5 oz.). When a water
valve is replaced, the fill volume must be checked.

TUR

N

Mounting
Plate

Screws

Mounting

Plate

Screw

Motor
Gear

Timing

Gear

Water Fill
Adjustment

Ice Maker

ON/OFF
Switch

PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT MID-POINT

CONTROL SETTING (2500 ++ V4)

Type A with Run/Start
Capacitor

65°F (18°C) Ambient

90°F (32°C) Ambient

Variable Speed

Standard

Variable Speed

Standard

Operating Time

74 to 84%

32 to 40%

100%

55 to 65%

Freezer Temperature

-2° to 2° F

-19° to -17° C

0° to 4° F

-18° to -16° C

-1° to 3° F

-18° to -16° C

-1° to 3° F

-18° to -16° C

Refrigerator Temperature

34° to 39° F

1° to 4° C

34° to 39° F

1° to 4° C

34° to 39° F

1° to 4° C

34° to 39° F

1° to 4° C

Low Side Pressure
(cut-in)

5 to 12 psig

43 to 83 kPa

5 to 12 psig

43 to 83 kPa

N/A

5 to 12 psig

43 to 83 kPa

Low Side Pressure
(cut-out)

-2 to 2 psig

-14 to 14 kPa

-2 to 2 psig

-14 to 14 kPa

-2 to 2 psig

-14 to 14 kPa

-2 to 2 psig

-14 to 14 kPa

High Side Pressure
(last 1/3 cycle)

90 to 105 psig

621 to 724 kPa

90 to 115 psig

621 to 793 kPa

120 to 135 psig

827 to 931 kPa

130 to 155 psig

896 to 1069 kPa

Wattage (last 1/3 cycle)

60 to 65

120 to 150

65 to 80

130 to 160

Amps (running)

.7 to 1.1

1.0 to 1.4

.9 to 1.3

1.1 to 1.5

Base Voltage

115 vac (127 vac max)

deFrOst speciFicatiOns

Cabinet Size

thermostat

heater

Cut-in

Cut-out

Watts

Ohms

23’, 23’ CD, 26’

25° F (-4° C)

47° F (8° C)

450

30

Elecrttonic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.

cOndenser Fan MOtOr

Watts

rpM

amps

3.1

1100 CW Opposite Shaft

0.03 Running

ice Maker speciFicatiOns

Electrical

115 vac (127 vac max)

Thermostat

Opens at 48° F ( 9° C), Closes at 15° F ( -9° C)

Heater Voltage

85 vac

ice Maker cOnnectOr pLUG cOnnectiOns

Wire number

Wire color

connects to:

1

Green/Yellow

Ground

2

Yellow

Water Valve

3

Black

Line

4

Light Blue

Neutral

iMpOrtant: pLease retUrn this sheet tO