Conversion, Before you begin, Tools and parts needed – Bosch HDS7052U User Manual

Page 4: Parts included, General information, Always provide adequate gas supply, Preparation, Turn all control knobs to the "off" position, Procedure

Advertising
background image

English 2

Before You Begin

Tools and Parts Needed

7 mm Socket Driver w/ 3" extension

Torx (T20)-head screwdriver

Adjustable Wrench

Flathead Screwdriver (1/8" or smaller)

Phillips Head Screwdriver

Parts Included

Conversion Kit Instructions

Conversion Sticker

4 LP Orifices

General Information

Always Provide Adequate

Gas Supply

This appliance is shipped from the factory for use with natural gas. Use this kit to
convert the appliance for LP gas use if necessary. Observe the following:

Be sure the range is converted for use with the appropriate gas before using it.

This appliance is designed to operate at a pressure of 10" of water column when
used with LP gas.

When checking for proper operation of the regulator, the inlet pressure must be at
least 1" greater than the operating (manifold) pressure above. When converting
for LP gas use, the pressure supplied to the regulator must be between 11" and
14" of water column. See step 2 "Convert Pressure Regulator from 5" to 10"
W.C.", next page.

The pressure regulator located in the inlet of the range manifold must remain in
the supply line.

Use a flexible metal appliance connector or rigid pipe to connect the Range to the
gas supply. The connector should have an I.D. of 1/2" and be 5' in length (Excep-
tion: Maximum connector length in Massachusetts installations is 3'). In Canada,
the connector must be single wall metal and not longer than 6'.

Preparation

CAUTION: Turn off Gas and Electricity

Before proceeding with the conversion; shut off the gas supply to the appliance
prior to disconnecting the electrical power.

1. Turn all control knobs to the "OFF" position.
2. Shut off the outside propane tank gas valve to the range.
3. Remove range power cord from electrical outlet or turn breaker off at breaker

box

Procedure

Conversion

Advertising
This manual is related to the following products: