Connecting the appliance, Water connection, Caution – Bosch B30BB830SS User Manual

Page 6: Connect the appliance to a drinking water line, Electrical connection, Warning, Avoid the risk of an electric shock

Advertising
background image

en-us

6

Connecting the appliance

After installing the appliance, wait at least 1 hour until

the appliance starts up. During transportation the oil in

the compressor may have flowed into the refrigeration

system.
Before switching on the appliance for the first time,

clean the interior of the appliance (see chapter

“Cleaning the appliance”).

Water connection

,

CAUTION:
Connect the appliance to a drinking water line.

The water may be connected only by a competent fitter

according to the local regulations of the appropriate

water supply company.
A cold water connection is necessary for operating

the automatic ice maker. The water pressure must be

between 25 and 120 p.s.i. (1,72 and 8,25 bar). The

installation must correspond to the local plumbing

regulations.
A separate shut-off valve should be installed in

the cold-water inflow.
The shut-off valve should not be located behind

the appliance. It is recommended that you mount

the shut-off valve directly next to the appliance or at

another place which is easily accessible.
When installing the water connection, pay attention to

the permissible installation area for the water mains.
For connection to the drinking water mains use only

water pipes which are suitable for drinking water.

Observe national regulations and the connection

conditions of the local water supply companies.

Electrical connection

,

WARNING:
Avoid the risk of an electric shock!

,

WARNING:
Insert into a grounded 3-phase socket. Never

remove grounding phase. Do not use any

adapters. Do not use any extension cables.

,

WARNING:
Non-compliance with these instructions may

result in death, fire or an electric shock.

Improper connection of the protective conductor

may result in an electric shock. If you are in

doubt whether the appliance has been grounded

properly, have the appliance tested by

a qualified electrician or service technician.

The socket must be near the appliance and also freely

accessible following installation of the appliance.
The appliance complies with protection class I.

Connect the appliance to 115 V/60 Hz alternating

current via a correctly installed socket with protective

conductor. The socket must be fused with a 10 to 16 A

fuse.
The appliance comes with a UL registered 3-wire power

cord. The appliance requires a 3-pole socket.
Please observe the following table with regard to this:

Check on the rating plate whether the indicated voltage

and current type correspond with the values of your

power supply. The location of the rating plate can be

found in the chapter entitled Customer service.

,

WARNING:
Never connect the appliance to electronic

energy saver plugs.
Our appliances can be used with mains and

sine-controlled inverters. Mains-controlled

inverters are used for photovoltaic systems

which are connected directly to the national grid.

Sine-controlled inverters must be used for

isolated applications (e.g. on ships or

in mountain lodges) which are not connected

directly to the national grid.

Appliance

Maximum simulta-

neous load

Fridge-

freezer

6.0 amps

Advertising
This manual is related to the following products: