Installation procedure, 9 caution, Preparing the installation – Bosch HCB50651UC User Manual

Page 10: Fitting the wall retainer, Press in the wall plugs flush with the wall, Unscrew screws, Screw on the angle bracket for the flue duct, Making the ceiling breakthrough, Making the wall breakthrough, Mounting the extractor hood on the wall

Advertising
background image

10

Installation Procedure

9

CAUTION

Ensure that there are no electric wires, gas or water

pipes in the area where holes are to be made.

Preparing the installation

1.

Mark a vertical center line on the wall from the ceiling

to the lower edge of the extractor hood.

2.

Align the drill template on the center line and the

bottom edge of the extractor hood and glue on.

3.

Mark positions for the screws and the contour of the

attachment area.

4.

Mark holes for the flue's angle brackets. The center of

the angle bracket is marked with a hole. Place the

angle brackets in the center of the center line, align

them horizontally and mark the positions of the holes.

Fitting the wall retainer

1.

Drill holes with Ø 5/16" (7.9 mm) for the angle

bracket.

2.

Press in the wall plugs flush with the wall.

3.

Screw screws (5x34 mm) into the wall plugs by hand

in order to spread the plugs apart.

4.

Unscrew screws.

5.

Screw on the angle bracket for the flue duct.

Making the ceiling breakthrough

1.

Using a spirit level, extend the center line of the drill

template to the ceiling.

2.

Mark the ceiling breakthrough (Ø 8 1/2" (216 mm)) at

least 4 5/8" (117 mm) away from the wall.

Making the wall breakthrough

1.

Using a spirit level, extend the center line of the drill

template to the ceiling.

2.

Depending on the curved section of the wall

breakthrough (Ø 8 1/2" (216 mm)) mark at least 26 1/

2" (660 mm) above the bottom edge of the extractor

hood.

Mounting the extractor hood on the wall

9

WARNING

RISK OF INJURY
The appliance is heavy. To move the appliance, 2

people are required. Use only suitable tools and

equipment.

1.

Initially remove the protective foil from the back of the

appliance and, following installation, remove foil

completely.

2.

Mark the upper holes on the wall.

Note: Ensure that the holes are horizontal and aligned

centered on the center line.

3.

Drill the upper holes. Maintain a distance of 1/4"

(6 mm) between the wall and screw head.

4.

Remove grease filter.

5.

Hang the extractor hood on the upper screws on the

wall.

6.

Mark the lower holes.

7.

Remove the extractor hood from the wall.

8.

Drill the lower holes.

9.

Hang the extractor hood on the upper screws on the

wall.

10.

Tighten the upper and lower screws by hand.

Mounting the back-pressure flap

Using 4 screws (4x8 mm), attach the back-pressure flap

to the extractor hood.

Connecting the air extractor (only for

ducted operation)

Note: If an aluminum pipe is used, smooth the

connection area beforehand.

1.

Attach exhaust air pipe and seal.

2.

Check whether the back-pressure flap works.

Advertising
This manual is related to the following products: