Before you begin, Tools and parts needed, Parts included – Bosch HCB50651UC User Manual

Page 8: Appliance dimensions

Advertising
background image

8

household installation. The voltage and frequency of the

appliance must match the electrical installation (see

rating plate).
The appliance complies with protection class 1 and must

only be operated in conjunction with a protective

conductor terminal.
An all-pole isolating switch with at least a 3 mm contact

gap must be fitted in the installation. This must remain

accessible after installation.
Only a qualified electrician who takes the appropriate

regulations into account may lay or replace the

connecting cable.
Follow all valid standards and laws.
Ensure that the electrical connection meets the

requirements of the latest version of all applicable

standards and laws in the appropriate country, especially

the following standards: National Electrical Code, ANSI/

NFPA 70*, or CSA Standards C22.1-94, Canadian

Electrical Code, Part 1 and C22.2 No.0-M91**.
Have a qualified electrical technician check the

grounding of the appliance.

Do not ground with a gas line.
No fuse protection in the neutral or grounding circuit.
Keep the installation instructions. Only connect the

appliance with a copper conductor. If possible, connect

the appliance to a metal cable guide directly to the fuse

box.
Ensure that the wire diameter meets the requirements of

the latest version of all applicable standards and laws in

the appropriate country, especially the following

standards: National Electrical Code, ANSI/NFPA 70*, or

CSA Standards C22.1-94, Canadian Electrical Code, Part

1 and C22.2 No.0-M91**.
Put a protecting hose that is listed in the U.L. or C.S.A. on

both ends of the connecting cable, that is, on the

appliance and on the fuse box.
For copies of the standards listed, contact:
* National Fire Protection Association Batterymarch Park

Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road

Cleveland, Ohio 44131-5575

Before You Begin

Tools and Parts Needed

Measuring tape
Pencil
Phillips screwdriver (Posidrive) #2
Drill with the following bits: 5/16" (7.9 mm) and 3/8"

(9.5 mm)
Spirit-level
Aluminum tape (DO NOT use insulating tape)
Exhaust channel (configuration depends on the

installation situation)
Additional sheet metal screws (if necessary for

installation of the exhaust air duct)
Saw

Parts Included

Extractor hood with fan, back-pressure flap
Lamp, already installed
Metal grease filter
Flue duct
Drill template
1x angle bracket for the flue duct
Instruction manual and installation instructions
6x screws, 5x45 mm
8x screws, 4x8 mm
2x washers
2x hollow wall plugs, 8x40 mm
4x hollow wall plugs, 10x50 mm
Torx adapter, 10 & 20

Appliance dimensions

A

Only for circulating-air mode:

Only for ducted operation:

7

7

/

8

(200 mm)

10

3

/

4

(273 mm)

13

3

/

16

(335 mm)

*Max. 45 13/16" (1164 mm)
*Min. 27 1/16" (687 mm)

*Max. 42 1/8" (1071 mm)
*Min. 27 1/16" (687 mm)

Advertising
This manual is related to the following products: