A. remove the two t20 torx head screws, Remove the 4-wire power cord (as supplied), B. remove the green grounding screw pe (t20 torx) – Bosch WTB86201UC User Manual

Page 14: Notice, Pull the old power cord out of the connection box, 9 caution, Leveling the dryer

Advertising
background image

14

1.

Unplug the current power cord being used from the

outlet/receptacle.

2.

To disconnect and/or reconnect a new power cord

you must remove the top cover of the appliance as

shown below.
A. Remove the two T20 torx head screws.

B. Push the top cover toward the rear of the appliance

and lift up.

3.

Open the connection box toward the rear of the

appliance by removing the T20 torx head screw

fastening the cover.

4.

Remove the 4-wire power cord (as supplied):
A. Remove the 3 Philips screws (2 labeled L and one

labeled N).

B. Remove the green grounding screw PE (T20 torx).
NOTICE: Be careful not to drop the screws into the

dryer.

5.

Loosen the strain relief clamp screw (Philips head) on

rear of the connection box.

6.

Pull the old power cord out of the connection box.

7.

Install the new power cord back through the strain

relief clamp.
NOTICE: Ensure the strain relief clamp has not been

moved and its clamping screw(s) are outside the rear

of the connection box.

8.

Ensure the terminal ends are long enough and are

formed (bent) so that no part of them (wires or

terminal ends) come in contact with connection box

enclosure.
NOTICE: Use only open-end spade lugs.

9.

Ensure the terminal ends are long enough and are

formed (bent) so they will align with the terminal block

fastening locations (screw holes).

10.

Reinstall the 2 terminal block screws (Philips head) at

locations L as shown below.

11.

If the ground wire shown below from N to PE is not

part of the 3-wire cord assembly you have it must be

obtained/purchased separately and it must be

installed.

12.

Install the last terminal block screw (Philips) and 1

grounding screw (T20 torx) at locations N and PE.

13.

Tighten the strain relief screw ensuring the power cord

cannot be pulled out of the connection box but not so

tight as cut the power cord insulation.

14.

Reinstall the connection box cover making sure all

wires are routed so they do not touch any part of the

enclosure and are secure.

15.

Reinstall the appliance top cover as previously

described in “2” point above.

Integrated electrical receptacle
This appliance is equipped with a 208/240V 15A

receptacle for use ONLY with Bosch washer listed below.

9

CAUTION

Do not use this receptacle to power any other

device.

If any other electrical device is plugged into this

receptacle Bosch will assume no liability.

9

CAUTION

Use integrated electrical receptacle only for these

Bosch washer listed:
WAP24200UC, WAP24201UC, WAP24202UC,
WAS24460UC, WAS20160UC, WAE20060UC.

Leveling the dryer

Importance of leveling the dryer
It is important that your dryer is level and that all four

dryer feet press with equal pressure against the floor.

This will help assure the quietest, most vibration-free use

of your dryer.

Advertising