Close the filter and re-insert it, Close the door, Notice – Bosch WTB86201UC User Manual

Page 28: Cleaning the heat exchanger, Unlock the maintanance flap and open it completely, Turn both locking levers towards each other, Pull out the heat exchanger cap, Remove the heat exchanger

Advertising
background image

28

6.

Close the filter and re-insert it.

7.

Close the door.

NOTICE: The filter should be rinsed once a year under

warm running water.

The filter must be dried thoroughly before being

replaced.

Cleaning the heat exchanger

The heat exchanger requires periodic cleaning

(recommended once per month under normal drying

conditions). The frequency of cleaning depends on the

amount and type loads being dried.

To clean the heat exchanger:

1.

If the dryer is hot, run on Air fluff/No heat program to

allow the dryer to cool down.

2.

Residual water may escape, place an absorbent cloth

under the maintanance flap.

3.

Unlock the maintanance flap and open it completely.

4.

Turn both locking levers towards each other.

5.

Pull out the heat exchanger cap.

6.

Remove the heat exchanger.
NOTICE: Do not damage the heat exchanger! Clean

with warm water only. Do not use hard/sharp-edged

objects!

7.

Rinse the heat exchanger and the cap on all sides with

a jet of water to completely remove all of the fluff.