Checking the ceiling, Installation procedure, 9 caution – Bosch HIB82651UC User Manual

Page 10: Calculating the installation height, Preparing the installation, Mark positions for the screws, Making the ceiling breakthrough, Make the ceiling breakthrough

Advertising
background image

10

Round pipes
An inner diameter of Ø 8" (200 mm) is recommended.
Flat ducts
The inner cross-section must correspond to the diameter

of the round pipes.
Ø 8" (200 mm) approx. 50.3 inches

2

(324 cm

2

)

Flat ducts should have no sharp deflections.

Use sealing strip for deviating pipe diameters.

Checking the ceiling

The ceiling must be flat, horizontal and adequately

load-bearing.

The depth of the bore holes must be the same length

as the screws.

The enclosed screws and wall plugs are suitable for

solid brickwork. Suitable fasteners must be used for

other structures (e.g. plasterboard, porous concrete,

poroton bricks).

Installation Procedure

9

CAUTION

Ensure that there are no electric wires, gas or water

pipes in the area where holes are to be made.

Calculating the installation height

1.

When selecting the installation height (P) of the

extractor hood, adhere to the minimum distances to

the cooktop, see Chapter Safety distances.

2.

Calculate distance from the ceiling to the lower edge

of the extractor hood, H = K - C - P.

3.

Calculate and note the distance from the ceiling to the

upper edge of the extractor hood (S).

Preparing the installation

1.

Align the drill template on the ceiling and glue it on.

When positioning the drill template, heed the position

of the control panel.

2.

Mark positions for the screws.

Making the ceiling breakthrough

1.

Mark the ceiling breakthrough (Ø 8 1/2" (216 mm))

using the drill template.

2.

Make the ceiling breakthrough

K

Ceiling height

C

Kitchen furniture height (standard height: 36"

(914 mm))

P

Distance from the lower edge of the extractor

hood to the cooktop

H

Distance from the ceiling to the lower edge of the

extractor hood = K - C - P

S

Distance from the ceiling to the upper edge of the

extractor hood = H - 2 6/16" (61 mm)

+

.

3

6

&

VWG