Installation

A. Interface PC and Machines

1. The Data Connector should be attached to the

network board on the back of the PC. The PC
must be Pentium 166 or better, have 32 mb
RAM minimum, a CD drive, a mouse and
Windows 98 or higher.

2. Carefully strip 1/4" of the insulation from the

black and red twisted pair wire. If too little
insulation is stripped, and insulation is inside
the connector, the network will not
communicate. If too much is stripped, the wires
will short. Refer to Figure 5.

3. The black/red twisted pair (Alliance Laundry

Systems recommends using American
Electronic Wire Co. part number 781816PFO -
2Z) wires should be connected to slots 1 and 2
(red from 1, black from 2). Refer to Figure 6.

B. Interfacing a Laptop to Machines

1. Attach the RS-485 cable to the Network Card

and insert the card into the PCMCIA Slot on the
laptop.

2. Attach the network cable to the RS-485 cable.

3. Carefully strip 1/4" of the insulation from the

black and red twisted pair wire. If too little
insulation is stripped, and insulation is inside
the connector, the network will not
communicate. If too much is stripped, the wires
will short. Refer to Figure 5.

4. Place a 120

1/2 Watt terminating resistor and

2 560

1/4 Watt bias resistors into the terminal

strip. Refer to Figure 3.

NOTE: One of the 560

1/4 Watt bias resistors

connects between the white and red wires of the
network cable. The other 560

1/4 Watt resistor

connects between the black and green wires of the
network cable.

Figure 1

NETWORK

BOARD

DATA

CONNECTOR

BLACK AND RED

TWISTED PAIR

WIRE

BLACK

RED

Figure 2

COM112N

NETWORK

CABLE

TERMINAL

STRIP

RS-485
CABLE

NBS-20

CARD

COM112N