D. Connecting the Repeater

to the PC

Refer to Figure 8

1. Attach one of the 210150 Network Cables to

segment 1 of the repeater.

2. Connect the RED and BLACK wires of that

Network Cable to the terminal strip coming
from the computer (RED to RED and BLACK
to BLACK). Do not connect the GREEN wire.

3. When repeater is used with a desktop PC, the

bias resistor in the repeaater must be removed.
Open the repeater and remove jumpers J3 and
J4. Refer to the manual included with the
repeater for specific instructions.

NOTE: Ensure that only the bias resistors that
correspond to segment one (PC connection) are
removed.

4. Connect one of the 210150 Network Cables to

segment 2 of the repeater.

5. Connect the RED and BLACK wires of that

Network Cable to the terminal strip going out to
one leg of the network (RED to RED and
BLACK to BLACK). Do not connect the
GREEN wire.

6. Terminate the last machine on this leg with a

120 Ohm 1/2 Watt resistor.

NOTE: Up to 124 nodes may be connected to any
given segment coming off the repeater. A total of
250 nodes may be connected to the network.

7. Repeat steps 4 – 6 for the remaining 2 segments

as required. There is no need to connect a cable
or a terminating resistor to an unused segment
on the repeater.

8. Connect the bayonet style connector of the wall

adapter to the 12 VDC input on the repeater.

9. Connect the wall adapter to a 120 VAC 60 Hz.

outlet.

Figure 7

6

H3

LOWER

UPPER/SINGLE

5 4 3 2 1

1 2 3 4 5 6

6

H3

LOWER

UPPER/SINGLE

5 4 3 2 1

1 2 3 4 5 6

6

H3

LOWER

UPPER/SINGLE

5 4 3 2 1

1 2 3 4 5 6

CONTROL1

SINGLE UNIT

6

H3

LOWER

UPPER/SINGLE

5 4 3 2 1

1 2 3 4 5 6

6

H3

LOWER

UPPER/SINGLE

5 4 3 2 1

1 2 3 4 5 6

6

H3

LOWER

UPPER/SINGLE

5 4 3 2 1

1 2 3 4 5 6

12

34

56

12

34

56

12

34

56

CONTROL2

STACKED UNIT

TERMINATING

RESISTOR

NOTE: For stacked units, wire must be run from
the top connector to the bottom connector before
moving on to the next machine.