Water Inc HP-RO-1000 User Manual

Model hp-ro-1000 undersink reverse osmosis system, User manual, Operating specifications

Advertising
background image

Model HP-RO-1000 Undersink Reverse Osmosis System

User Manual

HP-RO-1000-Manual Rev. 2-14

OPERATING SPECIFICATIONS

WARNING:

Before installing the system, make certain

your water supply complies with the

to do so may reduce the effectiveness
of the system and will void the warranty.
Consult your local water treatment utility

the quality for your water and use the table
below to record your results for future
reference.

Your Water

Pressure Range:

40–100 psi

(2.8–6.9 bar)

Temperature Range:

40–100°F

(4.4-37.8°C)

Total Dissolved Solids

< 2000 ppm

Maximum Hardness*

:

10 gpg

(171 mg/L)

:

< 0.1

Chlorine in Water Supply:

< 2 ppm

Water Supply pH Limits:

3-11

Turbidity:

5 NTU Max.

Date of Purchase:

*

If the hardness of your water is above 10 gpg (171 mg/L), lime scale will build

up rapidly on the membrane inside of the RO membrane cartridge. Scale
buildup will plug the RO membrane cartridge and make the system ineffective.
We do not recommend the HP-RO-1000 to be used with water in excess of 10 gpg
(171 mg/L) hardness, unless the water is softened prior to the reverse osmosis
system.

See your local dealer or water treatment specialist to reduce these substances
in your water.

HP-RO-1000 Dimensions:

System Dimensions

13" H x 15" W x 4.75" Dia

(330 x 381 x 120.6 mm)

Tank Dimensions

14.5" H x 11" Dia

(368 x 279 mm)

System Weight

23 lbs (10.4 kg)

Tank Capacity

3.2 gal (12.1 L)

Tools Required

Hand or Electric Drill

Phillips Screwdrivers

2 Adjustable Wrenches

Drill Bits: 1/8", 1/4" and 3/8"

File

Towel

Pencil

Safety Glasses

Needle-nose Pliers

Tape Measure

Utility Knife or Tube Cutter

(for plastic tubing)

Optional Materials

(For sinks without extra hole for faucet)

Hand or Electric Drill

Center punch

Drill Bits: 1/4" and 3/4"

Respirator

®

Tape

1-3/8" Bi-metal or Carbide

Tipped Hole-saw

NOTE: All tools listed will not be necessary for installation.

Read installation procedures before starting to
determine required tools.

Parts Included

Head Assembly

Drain Saddle Valve

Screws for mounting

Water Supply Adapter

Lead-free air gap drinking

water faucet

Quick-connect Fitting

Silicone grease

Storage Tank

Tank Valve

Faucet Adapter

®

Tape

Change Indication Sticker

3/8" Plastic Tubing

(red and blue)

1/4" Plastic Tubing

(white, red and green)

TDS Test Kit

Filter Cartridges:

HP-RO-1000 Specifications

Filter Kit (to be changed annually)
PART # WI-HP-RO-1000-FILTER-KIT
Filter Kit Includes:
PW-S2500R Cartridge (Yellow)
PW-C5000R Cartridge (Blue)
PW-C2500R Cartridge (Violet)

Membrane (to be changed every 3-5 years)
PART # WI-HP-RO-1000-MEMBRANE:
PW-RO75R Cartridge (Green)