43103 Rev A AU10

TABLE OF CONTENTS

JOB SPECIFICATION SHEET ...............................................1
EQUIPMENT CONFIGURATION ...........................................1
SAFETY INFORMATION ........................................................2
HOW TO USE THIS MANUAL ...............................................2
GENERAL AND COMMERCIAL INSTALLATION

INSTRUCTIONS .....................................................................2
CONTROLLER FEATURES ...................................................4
PLACING WATER CONDITIONING SYSTEM INTO

OPERATION ...........................................................................5
PROGRAMMING MODE ........................................................6
DISINFECTION OF WATER CONDITIONING SYSTEMS .....11
WIRING DIAGRAMS ..............................................................12
POWERHEAD ASSEMBLY ....................................................13
9100 CONTROL VALVE ASSEMBLY .....................................14
1600 BRINE VALVE SYSTEM ................................................15
9100 SECOND TANK ASSEMBLY .........................................16
3/4" METER ASSEMBLY ........................................................17
1" METER ASSEMBLY ...........................................................18
1-1/2" METER ASSEMBLY .....................................................19
9000/9100 BYPASS VALVE ASSEMBLY ...............................20
BYPASS VALVE ASSEMBLY .................................................21
2300 SAFETY BRINE VALVE.................................................22
2310 SAFETY BRINE VALVE.................................................23
2350 SAFETY BRINE VALVE.................................................24
PROBE KIT ............................................................................25
TROUBLESHOOTING ...........................................................26
9000/9100 METER FLOW DATA ............................................28
9000/9100 INJECTOR FLOW DATA

(1600 SERIES INJECTORS) ..................................................29
9100 CONTROL DIMENSIONS .............................................30
WATER CONDITIONER FLOW DIAGRAMS .........................31
SERVICE ASSEMBLIES ........................................................33

JOB SPECIFICATION SHEET

Job No: ___________________________________________
Model No: _________________________________________
Water Test: _________________________________________
Capacity Per Unit: ___________________________________
Mineral Tank
Size: ____________Diameter: __________ Height: _________
Brine Tank Size and Salt Setting per Regeneration: _________

1. Type of Timer:

a.

82 minute available regeneration time, 1/15 RPM

b. 164 minute available regeneration time, 1/30 RPM

2. Type of Meter:

Mechanical Valves (Gallon Settings)

Meter

Standard Range

Extended Range

3/4”

125 - 2,125

625 - 10,625

1”

310 - 5,270

1,150 - 26,350

1-1/2”

625 - 10,625

3,125 - 53,125

3. Timer Gallon Setting:________________________ Gallons
4. Regeneration Program Setting:

a. Backwash: ______________________________Minutes
b. Brine and Slow Rinse: _____________________Minutes
c. Rapid Rinse: _____________________________Minutes

_________________________Minutes

5. Drain Line Flow Control: _______________________ gpm
6.

_____________________________ gpm

7. Injector Size: ____________________________________

EQUIPMENT CONFIGURATION

Figure 1

800.322.WATER(9283)