21

PREPARING THE INSTALLATION LOCATION

IMPORTANT INSTALLATION INFORMATION

• All electric cooktops run off a single phase, three-

wire or four-wire cable, 240/208 volt, 60 hertz,
AC-only electrical supply with ground.

• Minimum distance between cooktop and

overhead cabinetry is 30

” (762 mm).

• Make sure the cabinets and wall coverings

around the cooktop can withstand the
temperatures (up to 93˚C [200˚F]) generated by
the cooktop.

A

B

I

C

D

H

E

F

G

K

L

J

30

” Min.

(762 mm)

** Do not obstruct these areas!

All dimensions are stated in inches and millimeters (mm).
Allow 2

” (50 mm) space below the armored cable opening to clear the electric cable and allow space

for installation of the junction box on the wall at the back of the cooktop.

30 inch Radiant Cooktop

LCE3081ST Radiant Cooktop

4" X 8" (102 mm x 203 mm)
opening to route armored
cable if panel is present.

Unit

Inch

mm

A

30-27/32

783

B

21-1/2

546

C

3-3/4

95

D

28-13/16

732

E

19-5/8

498

H

13/16

20

I

Max

13

330

K

2-1/2

64

L

24

610

F

Min

29-3/8

746

J

Min

5-23/32

145

G

Min

20-1/4

515