Installation instructions, Refrigerator installation – LG LSC23924ST User Manual

Page 13

Advertising
background image

13

Drill a ”

¼ (6.35 mm) hole in the water

pipe using a sharp bit.
Remove any burrs
resulting from drilling the
hole in the pipe. Take care
not to allow water to drain
into the drill. Failure to drill
a ”

¼ (6.35 mm) hole may result in reduced ice

production

or smaller cubes.

3. DRILL THE HOLE FOR THE VALVE

NOTE: Licensed plumbers must use only cooper tubing
NDA tubing #49595 or 49499 or Cross Link
Polyethylene (PEX) tubing.

4. FASTEN THE SHUTOFF VALVE

Fasten the shutoff valve to the cold water pipe with
the pipe clamp.

NOTE: Commonwealth of Massachusetts Plumbing
Codes 248CMR shall be adhered to. Saddle
valves are illegal and use is not permitted in
Massachusetts. Consult with your licensed

5. TIGHTEN THE PIPE CLAMP

Tighten the clamp screws until the sealing washer
begins to swell.

NOTE: Do not overtighten or you may crush the tubing.

6. ROUTE THE TUBING

Route the tubing between the cold water line and the
refrigerator.

Route the tubing through a hole drilled in the wall or
floor (behind the refrigerator or adjacent base cabinet) as
close to the wall as possible.

NOTE: Be sure there is sufficient extra tubing, [about 8 feet

coiled into 3 turns of about 10” (254 mm)

(2.4 m)

diameter] to

to move out from

allow the refrigerator

the wall after installation.

Vertical Cold
Water Pipe

Saddle-Type
Shutoff Valve

Pipe Clamp

Washer

Inlet End

Pipe Clamp

Clamp Screw

7. CONNECT THE TUBING TO THE VALVE

Place the compression nut and ferrule (sleeve) for
copper tubing onto the end of the tubing and connect it
to the shutoff valve. Make sure the tubing is fully inserted
into the valve. Tighten the compression nut securely.

Saddle-Type
Shutoff Valve

Packing
Nut

Outlet
Valve

Ferrule (sleeve)

Compression
Nut

1. SHUT OFF THE MAIN WATER SUPPLY

Turn on the nearest faucet to relieve the pressure on
the line.

Choose a location for the valve that
is easily accessible. It is best to connect
into the side of a vertical water pipe.
When it is necessary to connect into a
horizontal water pipe, make the
connection

rather

to the top or side,

than at the bottom, to avoid drawing
off any sediment from the water pipe.

2. CHOOSE THE VALVE LOCATION

INSTALLATION INSTRUCTIONS

Install the shutoff valve on the nearest frequently used
drinking water line.

REFRIGERATOR INSTALLATION

plumber.

NOTE: Commonwealth of Massachusetts Plumbing Codes
248CMR shall be adhered to. Saddle

valves are

Massachusetts.

illegal and use is not permitted in

Consult

plumber.

with your licensed

Advertising
This manual is related to the following products: