Communication parameters, Command reference list – LG 42CS570 User Manual

Page 74

Advertising
background image

ENGLISH

74

EXTERNAL CONTROL DEVICE SETUP

Communication Parameters

y

y

Baud rate: 9600 bps (UART)

y

y

Data length: 8 bits

y

y

Parity : None

y

y

Stop bit: 1 bit

y

y

Communication code: ASCII code

y

y

Use a crossed (reverse) cable.

Command reference list

COMMAND1

COMMAND2

DATA

(Hexadecimal)

COMMAND1

COMMAND2

DATA

(Hexadecimal)

01. Power

k

a

00 - 01

12. OSD Select k

l

00 - 01

02. Input Select x

b

(See p.76)

13. Remote

Control

Lock Mode

k

m

00 - 01

03. Aspect

Ratio

k

c

(See p.76)

14. Treble

k

r

00 - 64

04. Screen

Mute

k

d

00 - 01

15. Bass

k

s

00 - 64

05. Volume

Mute

k

e

00 - 01

16. Balance

k

t

00 - 64

06. Volume

Control

k

f

00 - 64

17. Color

Temperature

x

u

00 - 64

07. Contrast

k

g

00 - 64

18. Energy

Saving

j

q

(See p.77)

08. Brightness

k

h

00 - 64

19. Auto

Configuration

j

u

(See p.77)

09. Color

k

i

00 - 64

20. Channel

Add/Del

m

b

00 - 01

10. Tint

k

j

00 - 64

21. Key

m

c

(See p.77)

11. Sharpness

k

k

00 - 64

22. Backlight

m

g

00 - 64

COMMAND1 COMMAND2

DATA00

(Hexadecimal)

DATA01

(Hexadecimal)

DATA02

(Hexadecimal)

DATA03

(Hexadecimal)

DATA04

(Hexadecimal)

DATA05

(Hexadecimal)

23. Channel

Tuning

m

a

physical

program

high

major

program

low

major low

minor high minor low

attribute