Specifications 111

HP 460 W CS HE Power Supply (92%) specifications

Specification

Value

Input requirements

Rated input voltage

100 to 120 VAC, 200 to
240 VAC

Rated input frequency

50 Hz to 60 Hz

Rated input current

5.5 A at 100 VAC

2.6 A at 200 VAC

Rated input power

526 W at 100V AC input
505 W at 200V AC input

BTUs per hour

1794 at 100V AC input
1725 at 200V AC input

Power supply output

Rated steady-state power

460 W at 100V to 120V AC input
460 W at 200V to 240V AC input

Maximum peak power

460 W at 100V to 120V AC input

460 W at 200V to 240V AC input

HP 460 W CS Platinum Power Supply (94%) specifications

Specification

Value

Input requirements

Rated input voltage

100 to 120 VAC, 200 to
240 VAC

Rated input frequency

50 Hz to 60 Hz

Rated input current

5.2 A at 100 VAC
2.5 A at 200 VAC

Rated input power

517 W at 100V AC input
496 W at 200V AC input

Btus per hour

1764 at 100V AC input
1694 at 200V AC input

Power supply output

Rated steady-state power

460 W at 100V to 120V AC input
460 W at 200V to 240V AC input

Maximum peak power

460 W at 100V to 120V AC input

460 W at 200V to 240V AC input

HP 750 W CS HE Power Supply (92%) specifications

Specification

Value

Input requirements

Rated input voltage

100 to 120 VAC, 200 to
240 VAC

Rated input frequency

50 Hz to 60 Hz

Advertising