Remote switching via internal telephone, Remote switching via external telephone, B 7 q 6 1 s – Auerswald 2206 USB User Manual

Page 42: B m f 7 w f, 6 1 s # f

Advertising
background image

42

Use the Remote Switching Relay (via Telephone)

On the system telephone COMfortel 1500/2500, COMfort 1000/
1200/2000 plus and smar-tel-i (only on COMmander Basic) the

relays can be switched comfortably via menu (see manual of the tele-
phone).

If you like to switch a remote switching relay from an internal telephone,
this telephone needs the remote switching authorization (in the default
factory setting all subscribers have the remote switching authorization).

You are in need of an analog DTMF telephone, an ISDN tele-
phone with DTMF signalling or a DTMF sender.

The PBX needs to be configured with the configuration program COM-
set for this purpose.

Remote Switching via internal Telephone

b 7 Q

6 1 S #

Switch on or off the 1st relay

(COMpact 2206/4410 USB: „TS“ on module slot B,

COMmander Basic: „TS11/TS12“)

public password

1: on, 0: off

or

2

Switch on or off the 2nd relay

(COMpact 2206/4410 USB: „TO“ on module slot B,

COMmander Basic: „TO11/TO12“)

or

3

Switch on or off the 3rd relay

(COMpact 2206/4410 USB: „REL“ on module slot B,

COMmander Basic: „REL3 com/no/nc“)

or

4

Switch on or off the 4th relay

(COMpact 4410 USB: „TS“ on module slot C,

COMmander Basic: „TS21/TS22“)

or

5

Switch on or off the 5th relay

(COMpact 4410 USB: „TO“ on module slot C,

COMmander Basic: „TO21/TO22“)

or

6

Switch on or off the 6th relay

(COMpact 4410 USB: „REL“ on module slot C,

COMmander Basic: „REL6 com/no“)

Remote Switching via external Telephone

b M

f

7 W f

Start remote Programming

external
telephone

remote switching and
programming MSN/DDI

tone
(1 sec)

continue
with DTMF

external
password

external acknowledgement tone
(1 sec continuous tone)

6 1 S # f

Switch on or off the 1st relay

(COMpact 2206/4410 USB: „TS“ on module slot B,

COMmander Basic: „TS11/TS12“)

1: on,
0: off

external acknowledgement
tone (1 sec continuous tone)

or

2

Switch on or off the 2nd relay

(COMpact 2206/4410 USB: „TO“ on module slot B,

COMmander Basic: „TO11/TO12“)

or

3

Switch on or off the 3rd relay

(COMpact 2206/4410 USB: „REL“ on module slot B,

COMmander Basic: „REL3 com/no/nc“)

or

4

Switch on or off the 4th relay

(COMpact 4410 USB: „TS“ on module slot C,

COMmander Basic: „TS21/TS22“)

or

5

Switch on or off the 5th relay

(COMpact 4410 USB: „TO“ on module slot C,

COMmander Basic: „TO21/TO22“)

or

6

Switch on or off the 6th relay

(COMpact 4410 USB: „REL“ on module slot C,

COMmander Basic: „REL6 com/no“)