Installing and Configuring the Tape Drive for the
NonStop NS-Series Integrity Server

M8705A Tape Drive Installation and User’s Guide 694638-001

2 -2

Configuration

4. Connect the CLuster I/O Module to a NonStop NS-series server.

5. Connect one end of the power cord to the unit’s AC power receptacle and connect

the other end to an AC power outlet.

6. Power on the tape drive.

Configuration

1. Issue an SCF ADD TAPE command. This is an example:

-> ADD TAPE $M8705A, SENDTO STORAGE, CLIM C1002531, LUN 1

You can specify backup and primary CPUs if you need to balance the processing
load to other CPUs.

2. After configuring the tape drive in SCF, issue the following command:

SCF> START TAPE $tape

Example:

SCF> START TAPE $M8705A

For complete details about the ADD and START commands, including command
syntax, see the SCF Reference Manual for the Storage Subsystem.

For more information on connecting tape drives to the CLIM, see the NonStop
CLuster I/O Module (CLIM) Installation and Configuration Guide.

Table 2-1. SAS Cables

Part Number

Description

AE466A

2M External Infiniband (SFF-8470) to Mini SAS (SFF-8088)
1 x SAS Cable

AE468A

4M External Infiniband (SFF-8470) to Mini SAS (SFF-8088)
1 x SAS Cable

Advertising