Environmental requirements, Supported sfps, Supported hbas – HP Cisco MDS 9124e Fabric Switch for BladeSystem c-Class User Manual
Page 55
Cisco MDS 9124e Fabric Switch for HP c-Class BladeSystem
55
Environmental requirements
To ensure proper operation, the switch must not be subjected to environmental conditions beyond
those for which it was tested. The ranges specified in Table 16 list the acceptable environment for
both operating and non-operating conditions.
Table 15
Environmental requirements
Supported SFPs
Do not use unsupported SFPs; they can affect switch operability. They may not fit correctlyand may
void your warranty. See Optional hardware kits for a list of supported SFPs.
For a complete list of supported devices, refer to the latest version of the HP StorageWorks SAN
design reference guide:
Supported HBAs
For a list of HBAs that have been tested and are known to work with the SAN switches, refer to the
latest version of the HP StorageWorks SAN design reference guide:
http://h18000.www1.hp.com/products/storageworks/san/documentation.htm
Condition
Acceptable range during operation
Acceptable range during non-operation
Ambient temperature
104°F/40 °C at sea level, derated
1 C per 1000 ft above sea level
-40°C to 70°C with maximum rate
of change of 20 C /hr
Humidity
5% to 90% relative humidity,
non-condensing
50% to 80% relative humidity,
non-condensing
Altitude
0 to 10,000 ft (3 km) above sea
level
0 to 40,000 ft (12 km) above sea
level
Shock
40 G, 2mS duration
140 G, 2mS duration
Vibration
0.5 G, 10 to 500 Hz
2.0 G, 5 to 500 Hz
Airflow
47 cubic ft per minute
None required