Diagnostic steps, If the enclosure does not initialize, Correcting enclosure ids – HP P2000 G3 MSA Array Systems User Manual

Page 48: Is the front panel fault led amber

Advertising
background image

48

Troubleshooting

If the enclosure does not initialize

It may take up to two minutes for the enclosures to initialize. If the enclosure does not initialize:

Perform a rescan.

Power cycle the system.

Make sure the power cord is properly connected, and check the power source that it is connected to.

Check the event log for errors.

Correcting enclosure IDs

When installing a system with drive enclosures attached, the enclosure IDs might not agree with the

physical cabling order. This is because the controller might have been previously attached to some of the

same enclosures during factory testing and it attempts to preserve the previous enclosure IDs if possible. To

correct this condition, make sure that both controllers are up, and perform a rescan using SMU or the CLI.

This will reorder the enclosures, but can take up to two minutes for the enclosure IDs to be corrected.
To perform a rescan using the CLI, type the following command:

rescan

To rescan using SMU:

1.

Verify that both controllers are operating normally.

2.

In the Configuration View panel, right-click the system and select Tools > Rescan Disk Channels.

3.

Click Rescan.

Diagnostic steps

This section describes possible reasons and actions to take when an LED indicates a fault condition. See

LED descriptions

on page 57 for descriptions of all LED statuses.

Is the front panel Fault LED amber?

Answer

Possible reasons

Actions

No

System functioning properly.

No action required.

Yes

A fault condition exists.

Check the LEDs on the back of the controller to narrow

the fault to a FRU, connection, or both.

Check the event log for specific information regarding

the fault.

Yes

A fault occurred.
If installing an I/O module FRU,

the module has not gone online

and likely failed its self-test.

Check the event log for specific information regarding

the fault.

Isolate the fault.

Contact an authorized service provider for assistance.

Replace if necessary.

If installing an I/O module FRU, try removing and

reinstalling the new I/O module, and check the event

log for errors.