Platform event filtering configuration – HP Lights-Out 100 Remote Management User Manual

Page 29

Advertising
background image

3.

Press the down arrow (

↓) key to scroll to IPMI. Press the Enter key.

4.

Choose one of these options based on server model:

ML110 G6 and DL120 G6 servers:

Press the down arrow (

↓) key to scroll to IPMI. Press the Enter key.

a.
b.

Press the down arrow (

↓) key to scroll to Realtime Sensor Data. Press the Enter key.

On ML150 G6 servers, scroll to Hardware Health Information by pressing the down
arrow (

↓) key. Press the Enter key.

On DL160 G6, DL160se G6, DL180 G6, and SL160z G6 servers, and DL165 and
SL165z G7 servers, scroll to the Hardware Health Information menu by pressing the down
arrow (

↓) key. Press the Enter key.

On DL170h G6, DL170e G6, SL170z G6, SL170s G6, and SL2x170z G6 servers, scroll
to the Hardware Health Information menu by pressing the down arrow (

↓) key, and then

scroll to the Ambient Sensor Health Information menu. Press the Enter key.

The message Loading data. Please wait appears. After this message disappears, the
Temperature and Voltage sensor data appears. This data is real-time data and is updated on
a periodic basis.

Platform event filtering configuration

The PEF Configuration screen enables you to configure LO100 to take selected actions on received
or internally generated event messages. These actions include powering down the system, resetting
the system, and triggering the generation of an alert.

To enable PEF functionality you must issue the following commands in the CLP:

cd map1
oemhp i 20 10 D0 18 00 12 01 03 D2
oemhp i 20 10 D0 18 00 12 02 3F 95

To configure a PEF for a particular sensor, click the PEF button to the far right of that sensor on the
Monitoring Sensors screen. The PEF button adjacent to each sensor opens a PEF Configuration
page for that sensor.

The PEF Configuration screen contains two sections: Current PEF Entries and Add PEF Entry. The
Current PEF Entries section includes Sensor Type, Sensor Name, PEF Action, and PEF Control
information. The Add PEF Entry section enables you set an action.

Initially, there are no entries are in the Current PEF Entries section because no PEFs are defined.
When PEF entries are defined, the PEF Control field is active and enables you to set the individual
entries to enabled, disabled, or deleted.